Operation Manual / Power2 850-M / 4 Product description
5 Operation and service / 5.3 Expected replacement intervals
© Copyright 2020 ABB. All rights reserved.
HZTL4061_EN
Rev.D
March 2020
5.3
Expected replacement intervals
u
For information on the expected replacement intervals of the components of the low-
pressure stage, see document
Operation Manual / Power2 … / 4.1 Low-pressure stage.
u
For information on the expected replacement intervals of the components of the high-
pressure stage, see document
Operation Manual / Power2 … / 4.2 High-pressure stage.
5.4
Stopping the engine
CAUTION
Residual heat in the low-pressure and high-pressure stage
If the residual heat in the low-pressure and high-pressure stage is not suffi-
ciently dissipated by the circulating lubricating oil, machine damage could
occur.
u
Observe the post-lubrication times and the oil pressure specified for
post-lubrication (see chapter Monitoring during operation / Lubricating
oil pressure).
Page
31
/
58