Operation Manual / A170-M.. - A175-M..
3 Removal and installation / 3.2 Removing the turbocharger
© Copyright 2022 ABB. All rights reserved.
HZTL4033_EN
Rev.K
January 2022
3.2
Removing the turbocharger
WARNING
Risk of tipping
If the turbocharger is not sufficiently supported or not supported at all dur-
ing removal and installation, it may tip over and cause severe injury to per-
sonnel or accidents resulting in fatalities.
u
Support the turbocharger at a suitable location.
u
Secure with lifting gear wherever possible.
u
If present: Loosen cable to speed sensor.
u
Disconnect all gas, air and lubricating oil pipes.
Fig. 12: Turbocharger suspension points
u
If present: Remove insulation segments on bearing casing and feet.
u
Attach lifting gear to the suspension lug of the bearing casing and through the boles on
the turbine-end foot.
Page
29
/
146
Summary of Contents for HT610580
Page 2: ......