Operation Manual / A170-M.. - A175-M..
7 Periodic maintenance / 7.2 Cleaning the filter silencer
© Copyright 2022 ABB. All rights reserved.
HZTL4033_EN
Rev.K
January 2022
Cleaning the absorption segments (81136)
u
Pull out and bend up the sheet-metal coverings (81137), and remove the absorption seg-
ments (81136).
u
Clean the absorption segments.
When cleaning, note that the absorption segments may only be cleaned lightly with pres-
surized air, a soft brush or a moist cleaning cloth.
u
Have any heavily contaminated absorption segments replaced by an ABB Turbocharging
Service Station.
Fitting the filter silencer
u
Insert the absorption segments (81136) into the sheet-metal coverings (81137).
u
Bend the sheet-metal coverings (81137) back to their original shape and insert into the
slotted guides in the filter silencer body (81135).
u
If the cleaning container is present on the filter silencer: Reinstall the water injection pipe.
Page