Operation Manual / A150-M56/66/57/67 - A155-M..
11 Dismantling and fitting, cartridge concept / 11.3 Removing the cart-
ridge group
© Copyright 2022 ABB. All rights reserved.
HZTL4032_EN
Rev.S
February 2022
11.3
Removing the cartridge group
Fig. 91: Removing insulation sheets
u
If present: Remove insulation sheets.
Fig. 92: Removing cartridge group 1
Product
Value X [mm]
A150-M
112 ±2 mm
A155-M
144 ±2 mm
Table 58: Threaded rod, value X
1. Apply two marking lines (M) to the left and right of the cartridge group and the bracket.
2. Support and fix the turbine casing.
3. Loosen the clamping nut (42201) (see
4. Screw threaded rod (42191) up to value X at the hexagon.
5. Lift the centering bush (42193) using the threaded rod (42191) and hold it firmly.
If the centering bush jams:
Remove the clamping nut and rotate the threaded rod upwards using a standard nut.
6. Rotate the clamping nut (42201) downwards until the stop is reached.
Page
139
/
198
Summary of Contents for HT613687
Page 2: ......