Operation Manual / TPL76-C32/-C33/-C34/-C35
5 Maintenance / 5.3 Cleaning the compressor during operation
© Copyright 2021 . All rights reserved.
HZTL2485_EN
Rev.G
July 2021
5.3.2
Wet cleaning using external water-pressure vessel
(XC3)
Operating state prerequisites for compressor cleaning with XC3
To be able to carry out a satisfactory cleaning process which has been
tested and is recommended by ABB Turbocharging, the following pre-
requisites must be fulfilled:
u
Engine load 50 – 85%
u
Start cleaning cycle according to following description
Wet cleaning
operation with XC3.
Operating procedure for compressor wet cleaning with XC3
Operating the water pres-
sure vessel
u
The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
u
Remove sealing plug (X).
u
Fill vessel with required volume of clean water (see
table Cleaning
parameters
).
u
Screw in sealing plug (X).
u
Push the valve activator (Y) against the spring and hold it for 10 ... 15
seconds until the entire volume of water has been injected.
Page
53
/