Operation Manual / TPS48-D/E.. - TPS61-D/E..
Taking out of operation
9
Shutting down the turbocharger
9.1
Page 114
Apr
il 2015
H
ZT
L2410_
EN
R
ev
is
ion
D
Fitting the cover plate
Close the opening in the turbine casing using the cover plate (A).
Fasten the cover plate on the turbine casing (51000) using the
fastening strips (51002), Verbus Ripp® Verbusripp washers (51003)
and nuts (51007) and screw it down securely on the support.
NOTICE
Thoroughly clean the fastening strips (51002) before fitting them. Apply
high-temperature grease to the stud threads (51006).
© Copyright 2015 ABB. All rights reserved.