Operation Manual / TPS44-F.. - TPS61-F..
Preliminary remarks
1
Turbocharger rating plate
1.7
Page 14
© Copyright 2016 ABB. All rights reserved.
A
ug
us
t2
01
7
H
ZT
L2
41
2_
E
N
R
ev
is
io
n
F
Explanation of the rating plate
The recommended replacement intervals and the corresponding opera-
tional limits are jointly defined with the engine manufacturer. This informa-
tion is specific to the system.
Operation above the indicated values n
Bmax
, t
Bmax
can considerably shorten the
recommended replacement intervals. In such cases, we recommend that you
contact the nearest official ABB Turbocharging service station.
n
Mmax
and t
Mmax
normally apply only when running at overload (110%) during tri-
als on the engine test bed. These limits can also be permitted during operation
for special applications. Operation above n
Mmax
and t
Mmax
is not permitted.
Non-observance of the recommended replacement intervals can increase the
risk of unpredictable component failures.
Positions of the rating plates
One rating plate (01) each is attached on the left and the right side of the
turbocharger bearing casing.
1.7.1
1.7.2