Operation Manual / TPL65-A10 / -A30
10 Mothballing the turbocharger / 10.1 Taking the engine out of opera-
tion for up to 12 months
© Copyright 2020 . All rights reserved.
HZTL2482_EN
Rev.E
March 2020
If the total acid number (TAN) is greater than 2 mg KOH/g, the following
mothballing measures are necessary after taking an engine out of opera-
tion:
u
Dismantle the turbocharger.
u
The rotor and the bearing parts must be removed by an official ABB
Turbocharging service station and refitted afterwards.
u
Clean all parts.
u
Machined, bright surfaces of steel and cast parts must be oiled with
anticorrosive oil.
u
Reassemble complete turbocharger.
Rotor turning in stack draught
If the rotor turns as a result of the stack draught:
u
Install blind flange between compressor casing outlet flange and
charge air duct.