Operation Manual / TPS48-D/E.. - TPS61-D/E..
4 Operation / 4.5 Stopping the engine
© Copyright 2020 . All rights reserved.
HZTL2410_EN
Rev.F
March 2020
NOTICE
Sealing of the speed sensor
The speed sensor is designed with a sealing lip and does not require
any additional gasket for assembly.
u
Connect cable connector to speed sensor.
u
Switch on lubricating oil supply to turbocharger.
4.4.3
Failure of speed measuring system
Possible reasons for failure of the speed measuring system are de-
scribed in the chapter Troubleshooting.
4.5 Stopping the engine
CAUTION
Stopping the engine of oil-cooled turbocharger version
Heat in the turbocharger must be dissipated by the further circulating
lubricating oil.
u
Post-lubricate for 15 … 20 minutes.
u
Maintain oil pressure of 0.5 … 1.0 bar for post-lubrication.
CAUTION
Stopping the engine of water-cooled turbocharger version
Heat in the turbocharger must be dissipated.
u
Allow turbocharger cooling water to run for 15 … 20 minutes after
stopping engine.
u
Allow oil lubrication to continue running until rotor comes to a stop.
Further post-lubrication is not required and not recommended.