Operation Manual / TPL69-A10 / -A30 ... TPL77-A10 / -A30
8 Disassembly and assembly / 8.7 Fitting the cartridge group
© Copyright 2020 . All rights reserved.
HZTL2481_EN
Rev.D
March 2020
u
Check that nuts (90458) on three safety segments have been
tightened.
u
Fasten lifting device (90190) complete with shackle (90195) to front
side of flange (
F
).
u
Fit O-ring (76040).
u
Remove support angle. (90025)
u
Fit four guide studs (90320).
u
Carefully put compressor casing internal part complete with wall in-
sert and diffuser over guide studs.
u
Remove the guide studs (90320) and fit the studs (74026 / 74029).
If provided
u
Use studs [10x 74029 and 2x 74026 (each screwed in at top and bot-
tom)].
CAUTION
Locked safety segments (76080) during assembly
The safety segments (
76080
) are not in operating position. Additional
axial securing of the two compressor casings (74000/76000) is not
guaranteed.
u
Fit four nuts (74027) complete with washers (74018), equally spaced
around circumference, and tighten.
Page