Operation Manual / TPL65-A10 / -A30
1 Preliminary remarks / 1.4 Storage of new turbochargers and spare
parts
© Copyright 2020 . All rights reserved.
HZTL2482_EN
Rev.E
March 2020
u
Seal the package. The better the external seal is designed, the more
permanent the protection.
Long-term storage of turbochargers
The turbochargers will be prepared for prolonged storage by ABB Tur-
bocharging on request. The package is equipped with a hygrometer (see
illustration).
The following measures are required every 6 months:
u
Check the hygrometer (02) in the sight-glass. There is an opening (01)
in the wooden crate which allows this check to be carried out. When
the display field has changed colour at the 70% level, the maximum
permissible humidity has been exceeded. In this case, the turbochar-
ger must be inspected by an ABB Turbocharging Service Station and
repacked.
u
Inspect the package for damage. If the package is damaged, the tur-
bocharger must be inspected by an ABB Turbocharging Service Sta-
tion and repacked.
After every 3 years the following work steps must be performed by an
ABB Turbocharging Service Station:
¡
Inspect the component
¡
Replace the desiccant agent
¡
Repackage the component.
NOTICE
Turbocharger ready for operation
If the 70% field of the hygrometer (02) has not changed colour and the
package is undamaged, the turbocharger can be put into operation
without any prior inspection by an ABB Turbocharging Service Station.
Unpacking the turbochargers
The corrosion protection effect ends after the material is unpacked from
the VCI package.
To avoid the formation of condensation, the surroundings and the con-
tent of the package must have the same temperature during unpacking.
Page
8
/
117