FEP630, FEH630
ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D
107
Menu: Sensor Setup
NOTICE
Damage to components!
Damage to the flowmeter sensor due to incorrect setting of the excitation current possible.
Note
Menu only available if function ‘Backwards Comp.’ has been ordered and activated (see menu ’Device Setup/...Transmitter/...Feature
Settings‘).
If the function Backwards Comp. is activated, the transmitter can also be used with older transducers.
Setting the parameters in accordance with the specification on the name plate of the older sensor.
Menu / parameter
Description
Sensor Setup
Sensor Type
Select the sensor type:
• Standard QmaxDN: For ProcessMaster, HygienicMaster.
Meter Size
Setting the nominal diameter in accordance with the value provided on the name plate of the flowmeter sensor.
Value range: DN1 to 2400
Se Span
Setting the span in accordance with the value provided on the name plate of the flowmeter sensor.
Se Zero
Setting the zero point in accordance with the value provided on the name plate of the flowmeter sensor.
Line Freq
Selection of the mains frequency of the power supply (50Hz or 60Hz)
Excitation Freq.
Setting the excitation frequency in accordance with the value provided on the name plate of the flowmeter sensor.
Range: 30 & 25Hz, 15 & 12.5Hz, 7.5 & 6.25Hz, 3.75 & 3.125Hz
Set Point Curr.
Adjustment of the excitation current of the sensor coils.
Setting parameter to 200 mA only for models FEP321, FEP521, FEH321, FEH521.
For all other sensors contact ABB Service.
Pre. Amp
Selection whether a preamplifier exists in the flowmeter sensor or not
Older transducers with sensor sizes smaller than DN 10 or signal cables longer than 50 m (164 ft) have a preamplifier.
Calibration flag
Set to ‘1’ as soon as all parameters have been set in the setup menu of the sensor.
Sensor TFE Function
This activates or deactivates full pipe detection (TFE = complete fill electrode).
Software history
In accordance with NAMUR recommendation NE53, ABB offers a transparent and traceable software history.
Device software package FEx630 (device firmware package)
Design
Issue date
Type of change
Description
Ordering number
00.04.00 2/3/2017
First
publication –
3KXF002044U0100_00.04.00
00.04.01
6/27/2017
Bug fixing
Piston pumps filter
3KXF002044U0100_00.04.01
00:05:00 1/12/2018
Bug
fixing
Integrated
Polish language
3KXF002044U0100_00.05.00
7/1/2000
2018
Bug fixing
PROFIBUS DP® and Modbus® integrated. New bootloader
3KXF002044U0100_01.07.00
Change from one to two columns