background image

ABB i-bus

®

 KNX 

Parameters 
 

 

AC/S 1.x.1 | 2CDC508198D0211 Rev. A   453 

7.19 

Temperature Scheduler BACnet ASM 

7.19.1 

General 

 

This application-specific automation module (ASM) is a timer for temperatures. The switching times are 
parametrized by other BACnet devices via the BACnet interface of the application controller. The switching 
times can be viewed via the web user interface. 

The application controller outputs the switching command on the KNX bus and on the ASM output socket. 

The application controller ensures that the switching commands are executed, even if there is a 
malfunction in the BACnet system.  

 
 

Note  

It is essential the clock in the application controller is set to operate this module. 

 
 

7.19.2 

Settings 

 

General 

You will find descriptions of the global settings (Name, Description, Reinstall, BACnet, WebUI) i

chapter 

7.3, Global ASM settings

. 

 

Summary of Contents for i-bus KNX AC/S 1.x.1 Series

Page 1: ... PRODUCT MANUAL ABB i bus KNX AC S 1 x 1 Application Controller ...

Page 2: ......

Page 3: ...n IP network ports 13 3 Product overview 14 3 1 Product overview 14 3 2 Ordering details 14 3 3 AC S 1 1 1 Application Controller Basic 15 3 3 1 Dimension drawing 16 3 3 2 Connection diagram 17 3 3 3 Operating and display elements 18 3 3 4 Technical data 19 3 3 4 1 General technical data 19 3 3 4 2 Device type 20 3 3 4 3 Description of inputs and outputs 21 3 4 AC S 1 2 1 Application Controller BA...

Page 4: ...tion program 35 4 6 3 Unloading ETS physical address application program 35 4 6 4 Device restart 35 4 6 5 Factory settings 35 4 7 Data point types 36 5 Mounting and installation 37 5 1 Information about mounting 37 5 2 Mounting on DIN rail 38 5 3 Supplied state 38 6 Commissioning 39 6 1 Prerequisites for commissioning 39 6 2 Commissioning overview 40 6 3 Assignment of the physical address 41 6 3 1...

Page 5: ...Monitor mode parameter page 66 7 2 3 5 SSH access parameter page 66 7 2 3 6 Log settings parameter page 67 7 2 3 7 SSL certificate parameter page 68 7 2 3 8 Connection settings parameter page 71 7 3 Global ASM settings 72 7 3 1 General 72 7 3 2 BACnet 73 7 3 3 WebUI 75 7 3 4 Info 75 7 3 5 Help 75 7 4 Automation ASM 76 7 4 1 General 76 7 4 2 Settings 76 7 4 3 Sockets 140 7 4 4 Group objects 140 7 4...

Page 6: ... 7 9 5 BACnet objects 276 7 9 6 WebUI 286 7 10 Heat generator ASM 294 7 10 1 General 294 7 10 2 Settings 295 7 10 3 Sockets 311 7 10 4 Group objects 318 7 10 5 BACnet objects 322 7 10 6 WebUI 330 7 11 Cooling distribution circuit ASM 338 7 11 1 General 338 7 11 2 Settings 339 7 11 3 Sockets 348 7 11 4 Group objects 355 7 11 5 BACnet objects 361 7 11 6 WebUI 368 7 12 Chiller ASM 374 7 12 1 General ...

Page 7: ...ts 433 7 16 5 BACnet objects 434 7 16 6 WebUI 435 7 17 Operating mode Scheduler BACnet ASM 443 7 17 1 General 443 7 17 2 Settings 443 7 17 3 Sockets 445 7 17 4 Group objects 445 7 17 5 BACnet objects 446 7 17 6 WebUI 447 7 18 ON OFF Scheduler BACnet ASM 448 7 18 1 General 448 7 18 2 Settings 448 7 18 3 Sockets 450 7 18 4 Group objects 450 7 18 5 BACnet objects 451 7 18 6 WebUI 452 7 19 Temperature...

Page 8: ...uilding dashboard 475 9 2 3 Navigation menu 475 9 2 4 ASM detailed view 475 10 Maintenance and cleaning 477 10 1 Maintenance 477 10 2 Cleaning 477 10 3 Software update 478 10 4 Support 478 11 Disassembly and disposal 479 11 1 Removal 479 11 2 Environment 480 11 3 Deleting data 480 12 Planning and application 481 12 1 Application examples 481 12 2 Several devices per system 481 13 Appendix 483 13 1...

Page 9: ...possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Reproduction transfer to third parties or processing of the content including sections thereof is not permitted without prior express written permission from ABB AG The product makes use of open source software You must accept the license agreement befo...

Page 10: ...isk hazards that will definitely result in death or serious injury unless avoided WARNING Indicates medium risk hazards that could result in death or serious injury unless avoided CAUTION Indicates low risk hazards that could result in slight or moderate injury unless avoided ATTENTION Indicates a risk of malfunctions or damage to property and equipment but with no risk to life and limb Example Fo...

Page 11: ...ber security risks To increase the stability security and robustness of its solutions ABB has introduced official robustness tests for Internet security as part of the product development process In addition the information below includes guidelines and mechanisms that you can use to improve the security of KNX systems 2 4 Preventing access to the different media The basis for any protection conce...

Page 12: ...c can be designed as a separate line Enabling the filter tables in the line coupler KNX only prevents attackers from gaining access to the whole system 2 6 IP cabling inside the building For building automation use a separate LAN or WLAN network with its own hardware routers switches etc Regardless of the KNX system apply the usual security mechanisms for IP networks These are examples MAC filter ...

Page 13: ...ionality or a server Use of manufacturer specific solutions or visualizations e g access via https 2 8 Open IP network ports The device uses the following network ports for data communication in the IP network It is to be ensured that only authorized systems have access to these network ports Port Limitation Protocol Remark 27360 TCP 20 minute SSH Only if SSH access has been activated 1900 TCP 15 ...

Page 14: ...ABB i bus KNX via the front bus connection terminal The software application Engineering Tool Software ETS is used for physical address assignment and for setting the parameters The device is ready for operation after connecting the bus voltage and the supply voltage Abbreviation Description A Application C Controller S MDRC X 1 Application X 1 KNX 2 KNX BACnet X X Version number x 1 2 etc Table 3...

Page 15: ... 15232 The device contains pre defined application specific automation modules ASM for the most common areas of application for instance the calculation of heat demand trends or schedulers You can create your own automation modules using a graphic logic editor The device has a web user interface for the display of data and operation this interface is generated automatically Commissioning is undert...

Page 16: ...ABB i bus KNX Product Overview 16 2CDC508198D0211 Rev A AC S 1 x 1 3 3 1 Dimension drawing Fig 2 Dimension drawing 2CDC072033F0015 ...

Page 17: ...ction diagram Legend 1 Label carrier 7 Ethernet LAN connection 2 KNX programming LED red 8 On LED green 3 KNX programming button 9 LAN LINK LED yellow 4 KNX connection 10 KNX telegram LED yellow 5 Cover cap 11 Reset factory settings button behind label carrier 6 Power supply connection Us 2CDC072062F0017 ...

Page 18: ...ernet connection available Flickering Data traffic via LAN KNX telegram On Supply voltage and KNX connection available Flickering Data traffic via LAN Reset behind label carrier Press for less than 2 seconds no reaction Press for 2 to 10 seconds device restart Retains configuration and last states Press for more than 10 seconds factory reset Deletes configuration and all states Table 5 Operating a...

Page 19: ...ding to EN 61140 Isolation category Overvoltage category III according to EN 60664 1 Pollution degree II according to EN 60664 1 SELV KNX safety extra low voltage SELV 30 V DC Temperature range Operation 5 45 C Transport 25 70 C Storage 25 55 C Ambient conditions Maximum air humidity 93 no condensation allowed Atmospheric pressure Atmosphere up to 2 000 m Design Modular DIN rail component MDRC Mod...

Page 20: ... Table 7 Device type AC S 1 1 1 Note ETS and the current version of the device application are required for programming The latest version of the application and corresponding software information are available for download from www abb com knx After import into ETS the application appears in the Catalogs window under Manufacturers ABB Heating Ventilation Air conditioning Automation Controller In ...

Page 21: ...pplied via PoE Power over Ethernet according to IEEE 802 3af Class 2 Connecting the device to 230 V may destroy it 3 3 4 3 2 KNX connection The supplied bus connection terminal is used to connect to the KNX bus 3 3 4 3 3 LAN connection The device connects to the network via an Ethernet RJ45 interface for LAN networks The network interface can be operated at a transmission speed of 10 100 Mbit s Ne...

Page 22: ...eas of application for instance the calculation of heat demand trends or schedulers You can create your own automation modules using a graphic logic editor The device has a web user interface for the display of data and operation this interface is generated automatically as well as an integrated BACnet IP gateway for the connection of the KNX system to the building control system and other higher ...

Page 23: ...ABB i bus KNX Product Overview AC S 1 x 1 2CDC508198D0211 Rev A 23 3 4 1 Dimension drawing Fig 5 Dimension drawing 2CDC072033F0015 ...

Page 24: ...ction diagram Legend 1 Label carrier 7 Ethernet LAN connection 2 KNX programming LED red 8 On LED green 3 KNX programming button 9 LAN LINK LED yellow 4 KNX connection 10 KNX telegram LED yellow 5 Cover cap 11 Reset factory settings button behind label carrier 6 Power supply connection Us 2CDC072062F0017 ...

Page 25: ...ernet connection available Flickering Data traffic via LAN KNX telegram On Supply voltage and KNX connection available Flickering Data traffic via LAN Reset behind label carrier Press for less than 2 seconds no reaction Press for 2 to 10 seconds device restart Retains configuration and last states Press for more than 10 seconds factory reset Deletes configuration and all states Table 8 Operating a...

Page 26: ...ding to EN 61140 Isolation category Overvoltage category III according to EN 60664 1 Pollution degree II according to EN 60664 1 SELV KNX safety extra low voltage SELV 30 V DC Temperature range Operation 5 45 C Transport 25 70 C Storage 25 55 C Ambient conditions Maximum air humidity 95 no condensation allowed Atmospheric pressure Atmosphere up to 2 000 m Design Modular DIN rail component MDRC Mod...

Page 27: ...o the software information on our homepage Table 10 Device type AC S 1 2 1 Note ETS and the current version of the device application are required for programming The latest version of the application and corresponding software information are available for download from www abb com knx After import into ETS the application appears in the Catalogs window under Manufacturers ABB Heating Ventilation...

Page 28: ...pplied via PoE Power over Ethernet according to IEEE 802 3af Class 2 Connecting the device to 230 V may destroy it 3 4 4 3 2 KNX connection The supplied bus connection terminal is used to connect to the KNX bus 3 4 4 3 3 LAN connection The device connects to the network via an Ethernet RJ45 interface for LAN networks The network interface can be operated at a transmission speed of 10 100 Mbit s Ne...

Page 29: ...r instance calculation of heat demand trends or schedulers You can create your own automation modules using a graphic logic editor The devices have a web user interface for the display of data and operation this interface is generated automatically The AC S 1 2 1 Application Controller BACnet also has an integrated BACnet IP gateway for the connection of the KNX system to the building control syst...

Page 30: ...n the KNX bus and therefore operate as a clock It is possible to record in the device the changes in any 50 values for up to 3 years You will find the description of the application specific automation modules ASM from chapter 7 3 This decentral device offers significantly higher reliability than automation functions in PC based building control systems 4 2 2 Web user interface The web user interf...

Page 31: ...ACnet device profile Advanced Application Controller B AAC Support for the BACnet properties BBMD Foreign Device and Notification Class The device is BACnet BTL listed The KNX values are formed in BACnet objects of type binary value and analog value If the BACnet object is defined in the device configuration as BACnet output write accesses from BACnet are denied with a BACnet error message 4 2 4 K...

Page 32: ...not relevant for this device 4 5 Integration in the i bus Tool The device possesses an interface to the i bus Tool The application controller can be found in the network and the web user interface opened using the i bus Tool You can download the i bus Tool free of charge from our homepage www abb com knx A description of the functions is provided in the i bus Tool online help ...

Page 33: ...s restored after failing previously due to a bus voltage failure On bus voltage recovery a corresponding message is output on the web user interface and the group objects are updated however not initially sent on the bus New values after bus voltage recovery are sent normally again 4 6 1 3 Supply voltage failure and recovery On the failure of the supply voltage the device stops its function and wi...

Page 34: ... Downloading describes loading a modified or updated application onto the device with ETS Note After a download with a change to the parameters the reaction is the same as after resetting the device in ETS If the application is downloaded again full download after it has been unloaded the reaction is the same as after an ETS reset After the application is unloaded or after an interrupted download ...

Page 35: ...ading ETS physical address application program On the use of the ETS function Unload Application the device stops its function and deletes its configuration including the physical address KNX and the IP configuration The device then has the factory settings and sets its IP address using DHCP 4 6 4 Device restart The device can be restarted by briefly pressing the Reset button 2 to 10 seconds see c...

Page 36: ...the data point types there is a distinction between main types and subtypes e g DPT main type DPT subtype DPT name 1 xxx 1 001 DPT_SWITCH 1 008 DPT_UPDOWN 1 100 DPT_HEAT COOL Main type Defines the length Subtype Defines the length and the unit If the term data point type DPT is used in general the complete data point type including the subtype is meant ...

Page 37: ...sing The device is ready for operation after connecting the bus voltage and the supply voltage Note The maximum permissible current on a KNX line must not be exceeded During planning and installation ensure that the KNX line is correctly dimensioned The device has a maximum current consumption of 12 mA DANGER Severe injuries due to touch voltage Feedback from differing phase conductors can produce...

Page 38: ...ard the DIN rail until the DIN rail holder engages The device is now mounted on the DIN rail Relieve the pressure on the top of the housing 5 3 Supplied state The device is supplied with the physical KNX address 15 15 255 the IP configuration is set to Obtain an IP address automatically For more information on the IP address see chapter 6 3 1 Network settings The device is ready for operation in t...

Page 39: ... 39 6 Commissioning 6 1 Prerequisites for commissioning To commission the device a PC with ETS is required along with a connection to the ABB i bus e g via a KNX interface The device is ready for operation after connecting the bus voltage and the supply voltage ...

Page 40: ...functions and rectify any bugs See chapter 10 3 Software update 5 Minimum parameterization of the device Set device clock See chapter 7 2 2 5 Clock parameter page Set users and passwords See chapter 7 2 2 4 WebUI Users parameter page Set encrypted access to the web user interface See chapter 7 2 3 7 SSL certificate parameter page 6 Parameterization of the device For a description of the commission...

Page 41: ...ct the connection to the device must be made using the KNX twisted pair TP Subsequent programming and downloads can be undertaken using the ETS function Direct IP connection via the Ethernet interface See chapter 6 5 11 Download reaction 6 3 1 Network settings DHCP Obtain an IP address automatically is enabled on the device as standard So the device obtains its IP address from a DHCP server which ...

Page 42: ...d IP address to the device along with the related subnet mask and the default gateway The DNS address must also be specified This address is required so that the device can resolve domains and therefore for example contact the NTP server for the time synchronization ATTENTION The IP configuration must match the network topology Otherwise it will not be possible to contact the device and it will be...

Page 43: ...ommissioning this can be obtained free of charge from the KNX online shop For more information on the installation of DCA see ETS help Note The application HVAC Application 1 0 and the DCA ABB AC S are supported in ETS 5 only from version 5 6 5 Earlier versions are not supported ETS is required to parametrize the device For information on how to use the i bus Tool see 4 5 Integration in the i bus ...

Page 44: ...AC S 1 x 1 6 5 Device Configuration App DCA 6 5 1 Overview Once DCA has been successfully installed an additional DCA tab appears in the device view in ETS Fig 9 Overview of DCA Legend 1 ASM library 4 ASM properties bar 2 Structure 5 Menu bar 3 Workspace ...

Page 45: ...re displayed in the ASM property bar for information Click to minimize and maximize the ASM library 6 5 3 Structure To structure the project e g parts of the building parts of the system you can add containers by clicking the symbol The containers are displayed in the workspace the ASMs are added to the containers using drag drop Containers can be nested one inside the other The web user interface...

Page 46: ...be changed by dragging The information and values displayed in the ASM tiles are only examples that provide an impression of how they are displayed on the web user interface This information does not contain any values from the device and also does not represent the ASM parameterization An exclamation mark in the top right corner of the ASM tile refers to an ASM input socket that still needs to be...

Page 47: ...vals and on leaving DCA If changes to the project have not yet been saved the following message is displayed If this message is displayed and you want to program the device download please first click Save otherwise the latest configuration will not be loaded into the device Edit Buttons for cutting copying pasting and deleting a selected element Undo and redo Buttons for using the undo and redo f...

Page 48: ...rnatively you can select more than one ASM using the mouse with the Control key on the keyboard pressed Settings Buttons for opening the project verification window the DCA device settings window and the device information DCA version number and legal disclaimer The following buttons are only available in the Linking view Slider Increase reduce size of Linking view Grid Show hide background grid i...

Page 49: ... recent arrangements can be restored if the same ASMs are selected on opening the Linking view again ASMs outside the field of view can be reached by scrolling or changing the zoom setting ASM input sockets The ASM input sockets are displayed in the ASM tiles on the left The module receives values from other ASMs via these objects Every input on an ASM must be linked It is not allowed to leave an ...

Page 50: ... The sockets available depend on the parameterization of the ASM Make the link by clicking an output socket with the mouse and dragging to the required input socket with the left mouse button pressed A green check mark indicates a possible link with the required input socket Make the link by releasing the mouse button Note If sockets are hidden due to modified ASM parameters their link will be del...

Page 51: ... The main type is also apparent from the color of the sockets It is only possible to link sockets of the same main type or also subtype DPT 1 xxx and DPT 1 xxx OK DPT 1 xxx and DPT 1 001 OK DPT 1 xxx and DPT 9 xxx Not possible DPT 1 001 and DPT 1 002 Not possible ASM input and output sockets have a symbol if they are linked to ASMs not currently shown in the Linking view Click the symbol to show t...

Page 52: ...g cutting and pasting a device You can copy the entire device including its parameters ASMs settings etc and the group addresses linked using the ETS functions Copy Cut and Paste Use the advanced Paste function to adjust the group addresses during the paste This works both within an ETS project and between two open ETS projects Note After the paste the IP address and the BACnet address must be cha...

Page 53: ...r ASMs not selected are not copied Copy all links All links are copied This includes on the one hand the links between the ASMs copied selected as well as the links to the ASMs not copied selected In this situation the links to ASM multiple input sockets and to ASM output objects are copied Links to normal ASM input sockets cannot be copied because these can only ever be linked to one ASM output s...

Page 54: ...y single change made in the ETS in chronological order Here the functions take into account every change in DCA on the application controller and every general change in the ETS project group address building structure other KNX device parameters The Undo and Redo function in ETS can also undo and redo every change outside DCA individually However it can only ever undo and redo changes within DCA ...

Page 55: ...changes to the project have not yet been saved the following message is displayed If this message is displayed and you want to program the device download please first click Save otherwise the latest configuration will not be loaded into the device A fast download to the device is possible using the device s Ethernet interface if the ETS function Direct IP connection is activated in the ETS settin...

Page 56: ......

Page 57: ...General settings for the web user interface are made on the web user interface and are described in chapter 7 2 3 Web user interface device settings You will find the ASM related settings in the web user interface in chapter 9 2 Web user interface The following chapters describe the parameters for the ASMs based on the parameter windows Parameter windows are structured dynamically so that further ...

Page 58: ...arameter defines how many KNX telegrams the device is allowed to send on the KNX bus per second If this value is exceeded the device saves the telegrams and sends them the next time possible If the value of a group object not yet sent changes in the meantime only the latest value is sent This parameter is also displayed in the DCA device settings and can be changed there ...

Page 59: ...the time synchronization You will find the general IP settings for the device in chapter 6 3 1 Network Settings 7 2 2 2 KNX parameter page Rate of telegrams Options Do not limit 1 2 3 5 10 20 This parameter defines how many KNX telegrams the device is allowed to send on the KNX bus per second If this value is exceeded the device saves the telegrams and sends them the next time possible If the valu...

Page 60: ... is disabled it is not possible to communicate with the device via BACnet BACnet device object instance number Options 0 194302 Definition of the BACnet device address Note The BACnet device address must be unique in the BACnet network and is not allowed to be assigned twice BACnet device object name Definition of the BACnet name of the device The device uses this name in the BACnet network BACnet...

Page 61: ...n of Yes option Dependent parameter s Foreign Device Address Information on the IP address and the port used by the BACnet Broadcast Management Device BBMD This setting must match the setting on the BBMD The information must always consist of the IP address followed by the port number IP address and port number must be separated by a colon e g 192 168 1 10 47808 Foreign Device Registration Time Op...

Page 62: ...interface User profile Rights admin Administrator This user has all rights Change everything in the ASM detailed view on the web user interface Change web user interface settings Undertake firmware updates Delete messages expert Expert This user has the following rights Change everything in the ASM detailed view on the web user interface user User This user has the following rights Change the norm...

Page 63: ...s must not be blocked e g by a firewall KNX The device clock is set via the KNX bus The KNX time server must be connected to the related device group objects BACnet The device clock is set via the BACnet bus The device clock must be set via the BACnet time synchronization function by the BACnet time server Selection of NTP option Dependent parameter s NTP server Information on the IP address or th...

Page 64: ...n the web user interface See chapter 9 2 1 Menu bar The button only appears after you have logged in If not otherwise stated all parameters on the web user interface apply to all users 7 2 3 1 System tools parameter page Restart device The device is restarted See chapter 4 6 4 Device restart Restart application The web user interface is restarted All user connections are closed ...

Page 65: ...ss and the IP configuration are retained All values and states saved are lost The configuration must be programmed again by means of an ETS download 7 2 3 3 KNX Programming mode parameter page On this page you can place the device in the KNX programming mode or deactivate again the KNX programming mode See chapter 6 3 Assignment of the physical address The current state is displayed and is synchro...

Page 66: ...in real time using the Monitor function For security reasons this access should only be activated if required and then deactivated again 7 2 3 5 SSH access parameter page Using this function you can grant the device manufacturer on request diagnostic access to the device if there is a fault You can limit the access to a specific number of hours and withdraw it at any time See chapter 10 4 Support ...

Page 67: ...e fault See chapter 10 4 Support You can export this log as a file using the Export button ATTENTION Only export the log on request from the device manufacturer and do not provide it to others because this file could contain private data Using the Log level menu you can set the level of detail for the log ATTENTION Only change this parameter on request from the device manufacturer because it affec...

Page 68: ...no longer be possible for others to read and change the data It is prerequisite for the encryption that both communication partners terminal device and application controller authenticate themselves using certificates For this purpose both communication partners must have a certificate that the other accepts as valid You can create a new certificate on the device and then install it as trusted on ...

Page 69: ...A 69 In the Additional host name IP address field you can specify additional addresses that can be used to communicate with the device and for which the certificate is to be used By default the device IP address set in ETS is always added to the certificate ...

Page 70: ...the device in the pem file format As soon as you have activated the secure data connection the web user interface is refreshed with the secure connection Unencrypted access to the device is then no longer possible The user admin can delete the SSL certificate again at any time The button is shown as soon as an SSL certificate has been installed on the device ...

Page 71: ...page You can set on this page for each user of the web user interface whether the user is automatically logged out from the web user interface after inactivity for security reasons If this function is activated set here the number of minutes of inactivity after which automatic user logout is to occur ...

Page 72: ...group objects and the BACnet objects Description Enter in this text field any notes and comments on the ASM This description is only displayed at this point and nowhere else Reinstall Options No checkbox cleared Yes checkbox selected After the successful download of an ASM to the device the parameters for the ASM are locked against changes in ETS If parameters need to be changed the ASM must be re...

Page 73: ...1 Rev A 73 7 3 2 BACnet This parameter page is only available on the AC S 1 2 1 Application Controller BACnet Endpoints enabled Enable all Options No checkbox cleared Yes checkbox selected Use this option to enable disable all BACnet objects in the ASM ...

Page 74: ...heckbox you can specify any name you require The BACnet object name must be unique within the device If the name you enter is already used by another BACnet object in the device DCA outputs an error message and does not allow the name to be saved In this situation the last name is restored ID The number of the BACnet object is generated automatically by default You can change the BACnet object num...

Page 75: ...ctivated the ASM is displayed without even logging into the web user interface For further information on user profiles see chapter 7 2 2 4 WebUI Users parameter page 7 3 4 Info The information dialog box contains general information on the ASM ID The unique ASM ID on the device This will be needed by the device manufacturer for diagnostics purposes if there is a fault Type Information on the ASM ...

Page 76: ... modules supplied with the application controller You can define the input and output sockets on the custom modules as required You can also define read only and other fields for the web user interface It is not possible to define group objects and BACnet objects directly from within custom ASMs Input and output sockets are to be used instead 7 4 2 Settings General You will find descriptions of th...

Page 77: ...mposite function block Imports a user defined function block fbxml file After import the composite function block is shown at the bottom left in the list of function elements in Own function blocks Print Options Print All Print Current Worksheet The size of the printout matches the scaling on the user interface Print Preview Options Full Preview Previews the current worksheet The size of the print...

Page 78: ...links the plug in to the device and then shows the live status of the device logic The IP address for the connection is taken from the ETS settings Simulation menu Offline simulation of the defined logic More information Worksheet The worksheet is where you create logical links To create a new worksheet click the symbol To rename the worksheet double click the tab field and overwrite it Properties...

Page 79: ...y reasons When a connection has been established the current states of the input sockets output sockets and the internal links are displayed Note that the Monitor function can only work if the logic in the device and the plug in is the same Simulation Simulation Stop Starts and stops the simulation Speeds Used to select simulation speeds Important for simulating timer functions such as the Calenda...

Page 80: ...cessing power If power is restored during this time the device continues to operate normally If the power failure exceeds the backup time the logic shuts down safely When power has been restored the device restarts Failure of the bus voltage If the bus voltage fails but the power supply is running the device continues to operate normally and saves all internal values Bus dependent calculations suc...

Page 81: ...ld in the Properties window The corresponding ASM input socket in the Linking view also has this name Sending outputs No DPT Abbr Name Visible Description 1 Any A Output Always 2 1 bit TE Telegram received Parametrizable Checkbox selected Every telegram received triggers a status send pulse with the value 1 0 The next calculation usually after 200 ms resets the value to 0 Parameters Name Value Vis...

Page 82: ...om the logic are forwarded to other ASMs You can enter a unique name for the element in the Name field in the Properties window The corresponding ASM output socket in the Linking view also has this name Inputs Nr DPT Abbr Name Visible Description 1 Any E Input Always Parameters Name Value Visible Description Data subtype According to DPT Always Selects the data point type ...

Page 83: ...y O Output Always Parameters Name Value Visible Description Linked to List of all MARKER OUTs Always Selects the MARKER OUT to be linked to the MARKER IN Marker output MARKER OUT Markers are used for distant links Links between worksheets are also possible A marker output is logically linked to one or more marker inputs set the parameters for the connection in the properties window Inputs No DPT A...

Page 84: ...Visible Description 1 1 bit A Output Always An AND element can be easily inverted to a NAND element by double clicking the output Parameters Name Value Visible Description Input count 2 16 Always Function Whenever a telegram is received the output starts a recalculation independently if the value has changed The output is 1 true if all inputs are 1 true E1 E2 A 0 0 0 0 1 0 1 0 0 1 1 1 Other Inputs...

Page 85: ...ble Description 1 1 bit A Output Always An OR element can be easily inverted to a NOR element by double clicking the output Parameters Name Value Visible Description Input count 2 16 Always Function Whenever a telegram is received the output starts a recalculation independently if the value has changed The output is 1 true if at least one input is 1 true I1 I2 A 0 0 0 0 1 1 1 0 1 1 1 1 Other Input...

Page 86: ...the output on an XOR element to invert it into an XNOR element Parameters Name Value Visible Description Input count 2 16 Always Function Whenever a telegram is received the output starts a recalculation independently if the value has changed The output is true 1 if there is an odd number of true 1 inputs I1 I2 I3 A 0 0 0 0 0 0 1 1 0 1 0 1 0 1 1 0 1 0 0 1 1 0 1 0 1 1 0 0 1 1 1 1 Other Inputs not c...

Page 87: ... clicking the related input output Inputs No DPT Abbr Name Visible Description 1 1 bit I1 Input Always Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters None Function Whenever a telegram is received the output starts a recalculation independently if the value has changed The input value is output negated I A 0 1 1 0 ...

Page 88: ...Always Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible Description Input count 2 16 Always Function Whenever a telegram is received the output starts a recalculation independently if the value has changed The output is true 1 if exactly one input is true 1 I1 I2 I3 A 0 0 0 0 0 0 1 1 0 1 0 1 0 1 1 0 1 0 0 1 1 0 1 0 1 1 0 0 1 1 1 0 ...

Page 89: ...exactly one has the value 1 while the other outputs are 0 The circuit shown ensures that this is the case If more than one of the three input values is 1 this results in a 1ofN operator is equal to 0 The AND logic gates therefore force the three output values to 0 Other Inputs not connected are treated as if they did not exist ...

Page 90: ...s 2 Same as input 1 I2 Input value Parametrizable Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible Description In 2 Checkbox Always Numerical value If the checkbox is cleared Data type as for input 1 Function The output is 1 if I1 is greater than I2 The output is 0 if I1 is less than or equal to I2 Whenever a telegram is received the output starts ...

Page 91: ...2 Same as input 1 I2 Input value Parametrizable Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible Description In 2 Checkbox Always Numerical value If the checkbox is cleared Data type as for input 1 Function The output is 1 if I1 is less than I2 The output is 0 if I1 is greater than or equal to I2 Whenever a telegram is received the output starts a ...

Page 92: ...ays 2 Same as input 1 I2 Input value Parametrizable Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible Description In 2 Checkbox Always Numerical value If the checkbox is cleared Data type as for input 1 Function The output is 1 if I1 is equal to I2 The output is 0 if I1 is not equal to I2 Whenever a telegram is received the output starts a recalcula...

Page 93: ... Always 2 Same as input 1 I2 Input value Parametrizable Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible Description In 2 Checkbox Always Numerical value If the checkbox is cleared Data type as for input 1 Function The output is 1 if I1 is not equal to I2 The output is 0 if I1 is equal to I2 Whenever a telegram is received the output starts a recal...

Page 94: ...Always 2 Same as input 1 I2 Input value Parametrizable Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible Description In 2 Checkbox Always Numerical value If the checkbox is cleared Data type as for input 1 Function The output is 1 if I1 is greater than or equal to I2 The output is 0 if I1 is less than I2 Whenever a telegram is received the output st...

Page 95: ...ways 2 Same as input 1 I2 Input value Parametrizable Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible Description In 2 Checkbox Always Numerical value If the checkbox is cleared Data type as for input 1 Function The output is 1 if I1 is less than or equal to I2 The output is 0 if I1 is greater than I2 Whenever a telegram is received the output star...

Page 96: ...s Parameters Name Value Visible Description Input count 2 16 Always Input parameters Name Value Visible Description Min Checkbox Always Enables input F on the element Checkbox If the checkbox is cleared 1 Minimum 0 Maximum Function Input F defines if MIN or MAX function is activated If F 0 the output sends the largest input value E1 E16 Function MAX is activated If F 1 the output sends the smalles...

Page 97: ...ways Parameters Name Value Visible Description Send trigger Yes No Always Checkbox Yes The output sends when the selector receives a value No The output does not send when selector receives a value Function If the selector has the value 1 input I1 is sent to the output If the selector has the value 0 input I0 is sent to the output Values received on unselected inputs are stored until the input is ...

Page 98: ...t can also be used as a send trigger In the example below the result of the MIN MAX element is always triggered for sending when the Update input receives a telegram The Send trigger parameter in 1 MUX must be activated Other If an unlinked input is selected the output value remains unchanged ...

Page 99: ...ters Name Value Visible Description Input count 2 16 Always Function The selector value defines which input value is sent to the output Values received on unselected inputs are stored until the input is selected The output is recalculated and updated every time if any of the inputs or Select receives a value Note The selector starts with the value 0 Exception If the value on the selected input or ...

Page 100: ...les enables the output Outputs No DPT Abbr Name Invertible Visible Description 1 Any A Output No Always Parameters Name Value Visible Description Control input triggers calculation Yes No Always Yes The output sends a value every time a value is received on the control input Function Control input 1 true The output sends every time an input value is received enabled Control input 0 false The outpu...

Page 101: ... a value that is not blocked If the None option is selected for the Blocked Value parameter the filter element forwards all values received Application examples A presence detector sends 1 bit values After a defined time it sends the value 0 to switch off the light Other appliances are not to react to this value 0 because they have their own timer control A push button or a key card triggers the s...

Page 102: ...meters Name Value Visible Description Input count 2 16 Always Function Whenever a telegram is received the output starts a recalculation independently if the value has changed An overflow will occur if the value from the addition is outside the DPT range If the value from the addition is greater than the maximum DPT value o S 0 o Ü 1 true If the value from the addition is less than the minimum DPT...

Page 103: ...low Parameters Name Value Visible Description Input count 2 16 Always Function Whenever a telegram is received the output starts a recalculation independently if the value has changed An overflow will occur if the value from the multiplication is outside the DPT range If the multiplication is greater than the maximum DPT value o P 0 o Ü 1 true If the value from the multiplication is less than the ...

Page 104: ...ne Function Whenever a telegram is received the output starts a recalculation independently if the value has changed An overflow will occur if the value from the subtraction is outside the DPT range If the value from the subtraction is greater than the maximum DPT value o D 0 o Ü 1 true If the value from the subtraction is less than the minimum DPT value o D 0 o Ü 1 true If the value from the subt...

Page 105: ...nction Whenever a telegram is received the output starts a recalculation independently if the value has changed An overflow will occur if the value from the division is outside the DPT range If the value from the division is greater than the maximum DPT value o Q 0 o Ü 1 true o F 0 false If the value from the division is less than the minimum DPT value o Q 0 o Ü 1 true o F 0 false If the value fro...

Page 106: ... 1 R Remainder Always Remainder of the division 2 1 bit F Error Always Indicates a division by 0 Parameters None Function Whenever a telegram is received the output starts a recalculation independently if the value has changed Remainder and error The dividend is divided by the divisor and the value from the division is within the valid range of the DPT Output of the remainder o R value o F 0 false...

Page 107: ... ss Default value 00 00 00 If the checkbox is cleared Parameter and socket according to KNX DPT 13 100 Range from 00 00 00 to 99 59 59 Values outside the range are set to the minimum or maximum value respectively If the Delay checkbox is selected the time value field is not visible Function If a new value is received during the delay the delay restarts and the old value is discarded The timer rese...

Page 108: ...he sensor detects a movement the lighting in the corridor is gradually switched on e g every 500 ms Monitoring receipt of cyclical telegrams Bus voltage failure download and restart In the event of bus voltage failure the timer stops and the input value is discarded Therefore the output sends no value on restart Other Inputs not connected are treated as if they did not exist ...

Page 109: ...Z Reset Parametrizable 1 yes 0 no Outputs No DPT Abbr Name Invertible Visible Description 1 1 bit A Output Yes Always 1 true as long as the timer is running Input parameters Name Value Visible Description On time Checkbox Always Activates input T On time Unsigned integer in s If the checkbox is cleared Reset Checkbox Always Activates input Z Reset Checkbox 2 If Checkbox 1 is cleared If the Reset i...

Page 110: ...put receives a 1 the timer restarts If Reset 0 false o If the timer is running and the input receives a 1 true it ignores it The timer continues running Exceptions If the On time input is not connected the element uses the value 00 00 30 If the On time input is negative the element uses the value 00 00 00 If the On time input has a value of 00 00 00 the output is always 0 Bus voltage failure downl...

Page 111: ...me Visible Description 1 Time S Start Parametrizable 2 Time E End Parametrizable 3 1 bit A Active Parametrizable Value 0 disables the element the output remains unchanged 4 1 bit GT Whole time Parametrizable Output is always 1 Outputs No DPT Abbr Name Visible Description 1 1 bit A Output Always Parameters Name Value Visible As input Start Time hh mm ss Default 00 00 00 Always Yes End Time hh mm ss...

Page 112: ...lated and updated accordingly Whole time input 1 true AND Active input 1 true o Output 1 true o The element reacts as if the start time and end time were both 00 00 Whenever a telegram is received the output starts a recalculation independently if the value has changed Exception handling and startup behavior The element does not work if The system time is invalid Start time or end time have invali...

Page 113: ...2 Time E End Parametrizable Defines the end time refers to corresponding parameters 3 1 bit A Active Parametrizable If Active 0 the output is always 0 refers to corresponding parameters 4 1 bit WT Whole time Parametrizable If Whole time 1 Start 00 00 00 and End 24 00 00 refers to corresponding parameters 5 7 Recurrence Daily Weekly Monthly Yearly see below 8 Date A Start Parametrizable Defines the...

Page 114: ...ve Bit 0 Monday Bit 6 Sunday 6 1 byte unsigned W Week Parametrizable Every week on Monthly recurrence input No DPT Abbr Name Visible Description 5 1 byte unsigned T Day Parametrizable Day of every 6 1 byte unsigned M Month Parametrizable month Yearly recurrence input No DPT Abbr Name Visible Description 5 1 byte unsigned T Day Parametrizable Day 6 1 byte unsigned M Month Parametrizable Month Janua...

Page 115: ...very week s on Day of every month s Every year s starts on the date set in the Duration section The Duration section specifies the dates between which the element is active All the parameters can also be set via inputs Selecting the corresponding As input checkbox activates the inputs Time section parameters Parameter name Value Description Start Time of day in minutes default 00 00 00 Sets the st...

Page 116: ...er name Value Description Every day s Optional 1 500 default 1 The element is activated on specific days e g every 4th day Every day s and Every weekday are mutually exclusive options Every weekday Optional See above The element is active from Monday to Sunday only Note Every day s starts from the date set in the Duration section ...

Page 117: ...ys of the week on which an event should be triggered every x weeks Parameter name Value Description Every week s on 1 500 default 1 The element is activated in specific weeks e g every 3rd week Monday Sunday 1 bit default false 0 Parameters from Monday to Sunday Note Every week s starts from the date set in the Duration section ...

Page 118: ...ch an event should be triggered every x months Parameter name Value Description Day of every 1 31 default 1 The element is activated on a specific day in a specific month e g every 3rd day of the month month s 1 500 default 1 The element is activated in specific months e g every 3rd month Note Day of every starts from the date set in the Duration section ...

Page 119: ...hould be triggered every x years Parameter name Value Description Recur every year 1 500 default 1 The element is activated in specific years e g every 3rd year On day 1 31 default 1 See above This defines the day of the month January December January December See above This defines the month Note Recur every year s starts on the date set in the Duration section ...

Page 120: ...s defined the calendar function is active from the start date onward Parameter name Value Description Start Calendar day selection Default 01 01 2016 Before this date the element is inactive No End Optional No End and End at Date are mutually exclusive Selecting No End activates the element indefinitely End at Date Optional Calendar day selection Default 01 01 2040 See above After this date the el...

Page 121: ...08198D0211 Rev A 121 Selecting As input The settings concerned are disabled and the parameters can be set via the inputs Startup behavior The element will not be active unless a valid date and or time are provided via the Start and End inputs ...

Page 122: ...ned 7 xxx 2 bytes signed 8 xxx 2 byte floating point 9 xxx 4 bytes unsigned 12 xxx 4 bytes signed 13 xxx 4 byte floating point 14 xxx Inputs No DPT Abbr Name Visible Description 1 See above E Input Always 2 See above F Factor Parametrizable 3 See above V Offset Parametrizable Outputs No DPT Abbr Name Visible Description 1 See above A Output Always Parameters Name Value Visible Description Factor S...

Page 123: ... data type is applied to the output The N CONV element can be used to divide a 2 byte unsigned value into an upper and lower byte The lower value is calculated using Factor 1 The unsigned upper 2 byte value is calculated using Factor 0 00390625 1 256 The unsigned upper 4 byte value is calculated using Factor 0 0000152587890625 1 65536 The conversion of a 1 byte unsigned value from a value range 0 ...

Page 124: ...s 2 1 bit IA Inverted output Always Inverted flip flop output status Parameters Initial value Initial value of the input Can only be used in combination with the Set initial value after restart parameter Note Selecting the checkbox sets the initial value to 1 but only with 1 bit values Clearing the checkbox default sets the initial value to 0 Set initial value after restart The initial value is us...

Page 125: ...t on the output Any initial values set can trigger an output change when the inputs receive an incoming signal A S R A new 0 0 0 0 0 0 1 0 0 1 0 1 0 1 1 0 1 0 0 1 1 0 1 0 1 1 0 1 1 1 1 0 Note As long as input R 1 the output is always 0 Bus voltage failure download and restart The values are stored The last output value is restored on restart ...

Page 126: ...t Always 0 counter counts 1 resets the counter to 0 and disables it 3 8 bits or higher Gr Threshold Parametrizable Counter threshold Reaching this threshold triggers an overflow at the output Outputs No DPT Abbr Name Visible Description 1 8 bits or higher W Value Always Counter value integer 2 1 bit Ü Overflow Always Counter threshold reached Parameters Name Value Visible Description Threshold Int...

Page 127: ...0 and disables it The output value is 0 Threshold input o Defines the counter threshold o Can only be entered if the Output value is connected Bus voltage failure download and restart The counter value is saved The output value is restored on restart The output value is updated the first time the counter value changes after restart Application examples Telegram counter counts the number of telegra...

Page 128: ...al value Always Current measured value 3 Numerical 1 byte or higher PF Proportional coefficient Parametrizable Controller gain 4 Numerical 1 byte or higher IZ Integral time Parametrizable Integral time in s typical value range 60 900 s Ci 1 Integral Time 5 Numerical 1 byte or higher DZ Derivative time Parametrizable Derivative time in s typical value range 1 10 s Cd Derivative Time 6 1 bit R Reset...

Page 129: ... type PD or PID Derivative time in s typical value range 1 10 s Derivative time as input Yes No If Controller type PD or PID Limit output value anti wind up Yes No Always Limits the output value to a range If this range is exceeded a limit is imposed on the integral element in the controller anti wind up Lower limit Floating point number default 0 Always Upper limit Floating point number default 2...

Page 130: ...r calculates a new output value in the cycle time for the logic calculation see Settings usually every 200 ms The output sends on value change If the ControlValue exceeds the Upper limit or Lower limit see parameters the values are limited accordingly and the IntegralValue is reduced If the Reset input 1 the integral value is set to 0 Exceptions For parameter inputs Proportional coefficient Integr...

Page 131: ... input variables The constant never triggers a recalculation Outputs No DPT Abbr Name Visible Description 1 Any O Output Always Parameters Name Value Visible Description Constant value According to DPT Always For entering a constant value Selecting the checkbox sets the initial value to 1 but only with 1 bit values Clearing the checkbox sets a value of 0 ...

Page 132: ...isible Description 1 Any E On Always Sends the value entered via the WebUI Parameters Name Value Visible Description Min value According to DPT Always Minimum value that can be entered via the WebUI Max value According to DPT Always Maximum value that can be entered via the WebUI Index Integer Always Defines the order in which the input values are displayed on the web user interface Small values d...

Page 133: ...is read only Inputs No DPT Abbr Name Visible Description 1 Any E0 Off Always Displayed value Parameters Name Value Visible Description Index Integer Always Defines the order in which the output values are displayed on the web user interface Small values displayed at the top Function The element name is applied as the description text in the web user interface ...

Page 134: ... you can combine and save it in a function block In this case the function block input is used instead of an input socket Outputs No DPT Abbr Name Visible Description 1 Any A Output Always Parameters Name Value Visible Description Short description According to DPT Always Default E Full description According to DPT Always Default Input Index According to DPT Always Default 0 ...

Page 135: ...s you can combine and save it in a function block In this case the function block output is used instead of an output socket Outputs No DPT Abbr Name Visible Description 1 Any E Input Always Parameters Name Value Visible Description Short description According to DPT Always Default A Full description According to DPT Always Default Output Index According to DPT Always Default 0 ...

Page 136: ...and check the function of the logic using the simulation 2 Copy the logic and replace the input sockets and output sockets with the function blocks FB IN and FB OUT of the same data type 3 Enter the following parameters for function blocks FB IN and FB OUT o Short description One or more letters that are displayed on the input and output of the function block o Full description Name of the functio...

Page 137: ...ic and choose Edit Create composite block 5 The following dialog window appears Enter the data saved with the function block The title must be unique 6 Click OK The composite function block is now stored and is available in Own function blocks on the left in the Element Selector window ...

Page 138: ...ion block 3 The following dialog window appears Enter a name for the destination file Enabling the Protected option encrypts the destination file Importing composite function blocks Select File Import composite function block Note Inverting the outputs of composite function blocks currently has no effect At the moment composite function blocks cannot be linked to internal markers ...

Page 139: ...the Properties window Rectangle The Rectangle element can be used to improve clarity for example by framing a logical operator You can adjust the angle of rotation width and height by dragging and dropping using the left mouse button or in the Properties window Line The Line element can be used to improve clarity You can adjust the angle of rotation width and height by dragging and dropping using ...

Page 140: ...rview of the ASM sockets for linking to other modules Input sockets Object name Data type Socket IN Configuration dependent An input socket appears if you select a Socket IN function element in the configuration The data point type is dependent on the function selected Signal value Configuration dependent Output sockets Object name Data type Socket OUT Configuration dependent An output socket appe...

Page 141: ...w of the ASM by clicking the ASM s tile A field is displayed on the web user interface for each function element of type WEB IN and WEB OUT used in your logic All users except the Viewer have access and can enter data In addition the states of all input sockets and output sockets are displayed for information ...

Page 142: ...plication controller KNX BACnet web user interface and ASM sockets You can select predefined templates in the ASM settings for the most frequent situations Only one value can be transferred per module The data point type used can be selected as required 7 5 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM setting...

Page 143: ...within the ASM are set automatically These interface parameters are visible but cannot then be changed Alternatively you can select all interface parameters as required by selecting the Freely configurable option In this way it is possible for example to set up bidirectional data exchange between several interfaces You will find the descriptions of the individual templates in the following section...

Page 144: ... of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types Use value after restart Options Last value Initial value This parameter defines which value is output on the web user interface and the ASM socket after starting the application controller until a new value is received in the group object Last...

Page 145: ...ue in the group object Yes checkbox selected After a start the module actively requests the current value via the group object using a KNX Value Read telegram Initial values Initial value This parameter defines the value that is output after downloading the module This value is output on the web user interface and the ASM socket until a new value in the group object overwrites it The value range i...

Page 146: ... Data point type Definition of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types Use value after restart Options Last value Initial value This parameter defines which value is output in the BACnet object on the web user interface and the ASM socket after starting the application controller until ...

Page 147: ...ue in the group object Yes checkbox selected After a start the module actively requests the current value via the group object using a KNX Value Read telegram Initial values Initial value This parameter defines the value that is output after downloading the module This value is output on the web user interface and the ASM socket until a new value in the group object overwrites it The value range i...

Page 148: ...tion of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types Use value after restart Options Last value Initial value This parameter defines which value is output on the web user interface and the ASM socket after starting the application controller until a new value is received in the group object ...

Page 149: ...ue in the group object Yes checkbox selected After a start the module actively requests the current value via the group object using a KNX Value Read telegram Initial values Initial value This parameter defines the value that is output after downloading the module This value is output on the web user interface and the ASM socket until a new value in the group object overwrites it The value range i...

Page 150: ... data point type Data point type Definition of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types Use value after restart Options Last value Initial value This parameter defines which value is output in the group object after starting the application controller until a new value is entered on the ...

Page 151: ...heckbox cleared Yes checkbox selected This parameter specifies whether the value is to be sent cyclically on the KNX bus No checkbox cleared The value is only sent on the KNX bus after a change Yes checkbox selected The value is sent on the KNX bus after every change and cyclically The cycle time is set in the Send cyclically values to KNX every parameter below and is restarted each time on sendin...

Page 152: ...one Main data point type Data point type Definition of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types Use value after restart Options Last value Initial value This parameter specifies which value is output on the ASM output socket after starting the application controller until a new value is ...

Page 153: ... the KNX bus The last value is always output on the ASM output socket Send cyclically values to KNX Options No checkbox cleared Yes checkbox selected This parameter specifies whether the value is to be sent cyclically on the KNX bus No checkbox cleared The value is only sent on the KNX bus after a change Yes checkbox selected The value is sent on the KNX bus after every change and cyclically The c...

Page 154: ...ue in the group object Yes checkbox selected After a start the module actively requests the current value via the group object using a KNX Value Read telegram Initial values Initial value This parameter defines the value that is output after downloading the module This value is output on the web user interface and the ASM socket until a new value in the group object overwrites it The value range i...

Page 155: ... BACnet Main data point type Data point type Definition of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types Use value after restart Options Last value Initial value This parameter defines which value is output in the group object and the ASM output socket after starting the application controlle...

Page 156: ... selected This parameter specifies whether the value is to be sent cyclically on the KNX bus No checkbox cleared The value is only sent on the KNX bus after a change Yes checkbox selected The value is sent on the KNX bus after every change and cyclically The cycle time is set in the Send cyclically values to KNX every parameter below and is restarted each time on sending after a change Selection o...

Page 157: ...e by BACnet Main data point type Data point type Definition of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types Use value after restart Options Last value Initial value This parameter defines which value is output in the group object and on the ASM output socket after starting the application co...

Page 158: ... the KNX bus The last value is always output on the ASM output socket Send cyclically values to KNX Options No checkbox cleared Yes checkbox selected This parameter specifies whether the value is to be sent cyclically on the KNX bus No checkbox cleared The value is only sent on the KNX bus after a change Yes checkbox selected The value is sent on the KNX bus after every change and cyclically The c...

Page 159: ...ue in the group object Yes checkbox selected After a start the module actively requests the current value via the group object using a KNX Value Read telegram Initial values Initial value This parameter defines the value that is output after downloading the module This value is output on the web user interface and the ASM socket until a new value in the group object overwrites it The value range i...

Page 160: ...y as follows ASM socket Input WebUI Display KNX Output to KNX BACnet None Aggregate function Options None Max Min Avg Or And Using the Aggregate function it is possible to connect several output sockets to one input socket at the same time As a result there are several different signals on the input socket This setting specifies the related calculation function necessary This function is shown gra...

Page 161: ...t socket Max The highest value currently present on the input socket is used Min The lowest value currently present on the input socket is used Avg The average of all values currently present on the input socket is calculated and used Or The input values are combined using a logical OR operator Value 1 Value 2 Value used 0 0 0 1 0 1 0 1 1 1 1 1 ...

Page 162: ...lue 1 Value 2 Value used 0 0 0 1 0 0 0 1 0 1 1 1 Main data point type Data point type Definition of the data point type that is transferred between the interfaces You will find further information on the data point types in chapter 4 7 Data point types The selection available may be restricted depending on the parameters above ...

Page 163: ...lses 0 255 9 xxx 2 byte floating point value o 9 o 9 001 temperature C o 9 002 temperature difference K o 9 003 kelvin hour K h o 9 004 lux Lux o 9 005 speed m s o 9 006 pressure Pal o 9 007 humidity o 9 008 parts million ppm o 9 010 time s o 9 011 time ms o 9 020 voltage mV o 9 021 current mA o 9 022 power density W m2 o 9 023 kelvin percent K o 9 024 power kW o 9 025 volume flow l h o 9 026 rain...

Page 164: ... enable o 1 004 rise o 1 005 alarm o 1 006 binary value o 1 007 step o 1 008 up down o 1 009 open close o 1 010 start stop o 1 011 status o 1 012 inversion o 1 013 dimming send type o 1 014 input type o 1 015 reset o 1 016 confirm o 1 017 tripping device o 1 018 layout o 1 019 window door o 1 021 logic functions o 1 022 scene o 1 023 shutter blind mode o 1 100 heat cool ...

Page 165: ...the send behavior The value is only sent on the KNX bus if the new value differs from the last value sent by the difference set The value 0 means that this function is not active and any value change is sent on the bus This function affects only the output on the KNX bus The last value is always output on the ASM output socket Send cyclically values to KNX Options No checkbox cleared Yes checkbox ...

Page 166: ...values Initial value This parameter defines the value that is output after downloading the module This value is output on the web user interface and the ASM socket until a new value in the group object overwrites it The value range is dependent on the data point type set ...

Page 167: ... the options that can be selected for the other interfaces are restricted to Output and Display For system related reasons the values from other ASMs are continuously present on the input socket while input values from KNX BACnet and the web user interface are transmitted dependent on the event As such if several interfaces are active at the same time the last value cannot be identified unambiguou...

Page 168: ... This function is shown graphically as appropriate on the input socket in the Linking view Depending on the selection the data point types DPT available may be restricted See following parameters None No Aggregate function Only one output socket can be connected to the ASM input socket Max The highest value currently present on the input socket is used Min The lowest value currently present on the...

Page 169: ...using a logical AND operator Value 1 Value 2 Value used 0 0 0 1 0 0 0 1 0 1 1 1 WebUI Options Display Display Set not available if the Input option has been selected for ASM socket Possible settings for the web user interface Display The value from the other interfaces is displayed on the web user interface and cannot be changed Display Set The value is displayed on the web user interface and can ...

Page 170: ...es e g web user interface are output in the group object Output to KNX The ASM has an output group object The values from the other interfaces e g web user interface are output in the group object None The ASM does not have a group object Selection of Input output or Output to KNX option Dependent parameter s Send value to KNX by a change of Options 0 1 670760 C Value range dependent on the data p...

Page 171: ... to KNX every parameter below and is restarted each time on sending after a change Selection of Yes option Dependent parameter s Send cyclically values to KNX every Options 00 10 00 01 00 00 23 59 00 hh mm ss Selection of Input or Input output option Dependent parameter s Read value at startup Options No checkbox cleared Yes checkbox selected No checkbox cleared The value is only sent on the KNX b...

Page 172: ... other interfaces is output in the BACnet object and cannot be changed via BACnet Read writable by BACnet The value can be read via BACnet and can also be changed via BACnet None The ASM does not have a BACnet interface Main data point type Data point type Definition of the data point type that is transferred between the interfaces You will find further information on the data point types in chapt...

Page 173: ...lses 0 255 9 xxx 2 byte floating point value o 9 o 9 001 temperature C o 9 002 temperature difference K o 9 003 kelvin hour K h o 9 004 lux Lux o 9 005 speed m s o 9 006 pressure Pal o 9 007 humidity o 9 008 parts million ppm o 9 010 time s o 9 011 time ms o 9 020 voltage mV o 9 021 current mA o 9 022 power density W m2 o 9 023 kelvin percent K o 9 024 power kW o 9 025 volume flow l h o 9 026 rain...

Page 174: ... enable o 1 004 rise o 1 005 alarm o 1 006 binary value o 1 007 step o 1 008 up down o 1 009 open close o 1 010 start stop o 1 011 status o 1 012 inversion o 1 013 dimming send type o 1 014 input type o 1 015 reset o 1 016 confirm o 1 017 tripping device o 1 018 layout o 1 019 window door o 1 021 logic functions o 1 022 scene o 1 023 shutter blind mode o 1 100 heat cool ...

Page 175: ...st value before device start is saved and reused The value parameterized further down in Initial value is used after the first download of the module to the application controller Initial value The value described further down in Initial value is used Initial values Initial value This parameter defines the value that is output after downloading the module This value is output on the web user inter...

Page 176: ...cket if the ASM input socket to KNX template or the Freely configurable template is selected with the ASM socket Input parameter Input for outputting a value from another module on one of the interfaces activated Signal value Configuration dependent Output sockets Object name Data type Value Configuration dependent The module has an output socket if the KNX to WebUI KNX to BACnet KNX to ASM output...

Page 177: ...WebUI KNX to BACnet KNX to ASM output socket template or the Freely configurable template is selected with the KNX Input parameter Input for the KNX value for output on the parameterized interfaces Telegram value Configuration dependent In Output Value Value Configuration dependent C R W T The module has an input output group object if the WebUI to KNX with update BACnet to KNX with update templat...

Page 178: ...e Value Configuration dependent Configuration dependent The module has a BACnet input object if the KNX to BACnet template or the Freely configurable template is selected with the BACnet Readable by BACnet parameter Input for the BACnet value for output on the parameterized interfaces Signal value Configuration dependent BACnet output objects Object name Object type Unit COV send condition Value V...

Page 179: ... current value is displayed on the web user interface for all configurations With the following configurations the value can also be changed on the web user interface WebUI to KNX template WebUI to KNX with update template Freely configurable template WebUI Display Set parameter ...

Page 180: ...e used to save an e mail address The module indication in ETS is static The indication http in the tile does not change 7 6 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM settings This module does not need a reinstall function and therefore does not have a corresponding option in the settings at variance with t...

Page 181: ...resses The specification of the protocol in compliance with the standards is validated and errors indicated with a red marking The protocols that can be used are dependent on the device used by the user and are not restricted by the application controller Destination addresses with up to 600 characters are supported 7 6 3 Sockets The module does not have any ASM sockets and can therefore not be li...

Page 182: ...rameters 182 2CDC508198D0211 Rev A AC S 1 x 1 7 6 6 WebUI Click the ASM to open the destination of the link With long destination addresses the end is truncated in the ASM tile However it will still function correctly ...

Page 183: ...c automation module ASM all KNX HVAC automation devices in a room can be displayed and operated on the web user interface The room display on the web user interface is generated automatically based on the ASM configuration This module also outputs the current states and values on ASM output sockets and in BACnet objects ...

Page 184: ...i bus KNX Parameters 184 2CDC508198D0211 Rev A AC S 1 x 1 7 7 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM settings ...

Page 185: ... received via KNX is only to be displayed on the web user interface or it can also be changed by the user The current value is output on the ASM output socket and in a BACnet object Display The room setpoint temperature is only displayed on the web user interface and cannot be changed Display set slave DPT 9 001 DPT 9 002 The room setpoint temperature can be changed on the web user interface This ...

Page 186: ... affect the indication on the web user interface Absolute setpoint temperatures The room thermostat uses absolute room setpoint temperatures e g 23 C For the new master slave interface a group object of type DPT 9 001 is used For the old master slave interface a group object of type DPT 6 010 is used Relative setpoint temperatures The room thermostat uses relative room setpoint temperatures e g 3 ...

Page 187: ...t socket and in a BACnet object This setting functions only with ABB and Busch Jaeger devices with the old master slave interface Heating cooling operating type Options None Display Display set slave This parameter specifies whether the heating cooling operating type from the room thermostat received via KNX is only to be displayed on the web user interface or it can also be changed by the user Th...

Page 188: ...ASM output socket and in a BACnet object Display set slave The operating mode can be changed on the web user interface The current value is output on the ASM output socket and in a BACnet object This setting functions only with ABB and Busch Jaeger devices with the old master slave interface Window status Options No checkbox cleared Yes checkbox selected This parameter specifies whether the room s...

Page 189: ...ling 4 pipe heating cooling Selects the fan coil unit blower convector The type selected affects the depiction on the web user interface and the number of valve control values None A fan coil unit is not used in the room 2 pipe heating The fan coil unit can only heat 2 pipe cooling The fan coil unit can only cool 2 pipe heating cooling The fan coil unit can heat and cool It is only connected via 2...

Page 190: ...On Off The additional heating stage does not have multiple settings KNX DPT 1 001 is used 0 100 The additional heating stage has multiple settings KNX DPT 5 001 is used Fan coil unit fresh air damper Options None Open Closed 0 100 Selects the fresh air damper This can also be the status of a VAV box Variable Air Volume None A fresh air damper is not used Open Closed The fresh air damper only has t...

Page 191: ...ng functions only with ABB and Busch Jaeger devices with the new master slave interface with group objects of type DPT 5 001 Display set slave DPT 5 010 The fan speed can be changed on the web user interface This setting functions only with ABB and Busch Jaeger devices with the old master slave interface with group objects of type DPT 5 010 Selection of Display or Display set slave DPT 5 001 optio...

Page 192: ... 5 Fan coil unit dew point sensor Options No checkbox cleared Yes checkbox selected This parameter specifies whether the status of the fan coil unit s dew point sensor is displayed on the web user interface and is to be output in the BACnet object and on the ASM output socket Fan coil unit level sensor Options No checkbox cleared Yes checkbox selected This parameter specifies whether the status of...

Page 193: ...ects the floor heating None Floor heating is not used in the room On Off The floor heating has a valve with the two settings open closed e g a solenoid valve KNX DPT 1 001 is used 0 100 The floor heating has a continuous valve e g a thermal or motorized valve KNX DPT 5 001 is used Selection of On Off and 0 100 option Dependent parameter s Floor temperature sensor Options No checkbox cleared Yes ch...

Page 194: ... 0 100 option Dependent parameter s Cooling ceiling dew point alarm sensor Options No checkbox cleared Yes checkbox selected This parameter specifies whether the status of the dew point alarm sensor is displayed on the web user interface and is to be output in the BACnet object and on the ASM output socket Split unit Options No checkbox cleared Yes checkbox selected This parameter specifies whethe...

Page 195: ...Fan coil unit valve heating 5 001 Output Fan coil unit valve cooling 5 001 Output Fan coil unit valve 5 001 Output Fan coil unit additional stage heating 1 001 5 001 Output Fan coil unit fresh air damper 1 019 5 001 Output Fan coil unit fan speed 5 001 5 010 Output Fan coil unit fan manual 1 011 Output Fan coil unit dew point sensor 1 001 Output Fan coil unit level sensor 1 001 Output Radiator val...

Page 196: ...or the Controller On Off parameter Outputs whether the room thermostat is switched on or off Signal value 0 Off 1 On Heating cooling operating type DPT 1 100 The module has this output socket if any option except None is selected for the Heating cooling operating type parameter Outputs the current heating cooling operating type Signal value 0 Cooling 1 Heating Operating mode DPT 20 102 The module ...

Page 197: ...ndby 3 Economy 4 Building Protection Window status DPT 1 019 The module has this output socket if the Yes option is selected for the Window status parameter Outputs the window status Signal value 0 Closed 1 Open Presence detector DPT 1 018 The module has this output socket if the Yes option is selected for the Presence detector parameter Outputs the presence status Signal value 0 Not occupied 1 Oc...

Page 198: ...ion control value on the fan coil unit for heating Signal value 0 100 Fan coil unit valve cooling DPT 5 001 The module has this output socket if the 2 pipe cooling option or the 4 pipe heating cooling option is selected for the Fan coil unit parameter Outputs the valve position control value on the fan coil unit for cooling Signal value 0 100 Fan coil unit valve DPT 5 001 The module has this outpu...

Page 199: ...s in the module If any option except None is selected for the Fan coil unit parameter and the Open Closed option is selected for the Fan coil unit fresh air damper parameter DPT 1 019 Signal value 0 Closed 1 Open If any option except None is selected for the Fan coil unit parameter and the 0 100 option is selected for the Fan coil unit fresh air damper parameter DPT 5 001 Signal value 0 100 Output...

Page 200: ...l unit dew point sensor parameter Outputs the signal value from the dew point sensor in the fan coil unit Signal value 0 Off 1 On Fan coil unit level sensor DPT 1 001 The module has this output socket if any option except None is selected for the Fan coil unit parameter and the Yes option is selected for the Fan coil unit level sensor parameter Outputs the signal value from the level sensor in the...

Page 201: ...ted for the Floor temperature sensor parameter Outputs the floor temperature Signal value 273 670760 C Cooling ceiling valve DPT 1 001 DPT 5 001 The data point type for the output socket is dependent on the settings in the module If the On Off option is selected for the Cooling ceiling parameter DPT 1 001 Signal value 0 Off 1 On If the 0 100 option is selected for the Cooling ceiling parameter DPT...

Page 202: ...Yes option is selected for the Split unit parameter Outputs the fan speed in the split unit Signal value 0 100 Split unit status DPT 20 105 The module has this output socket if the Yes option is selected for the Split unit parameter Outputs the status of the split unit Signal value 0 Auto 1 Heat 2 Morning Warmup 3 Cool 4 Night Purge 5 Precool 6 Off 7 Test 8 Emergency Heat 9 Fan only 0A Free Cool 0...

Page 203: ...ode Room 20 102 1 byte x x x x Input Controller Status HVAC slave Room 5 010 1 byte x x x x Output Operating mode normal slave 20 102 1 byte x x Input Operating mode override slave Room 20 102 1 byte x x x x Input Window status Room 1 019 1 bit x x x x Input Presence slave Room 1 018 1 bit x x x x Input Rel humidity Room 5 001 1 byte x x x x Input CO2 value Room 9 008 2 bytes x x x x Input Fan coi...

Page 204: ...om 1 001 1 bit x x x x Input Fan coil unit level sensor Room 1 001 1 bit x x x x Input Radiator valve Room 1 001 5 001 1 bit 1 byte x x x x Input Floor heating valve Room 1 001 5 001 1 bit 1 byte x x x x Input Floor temperature sensor Room 9 001 2 bytes x x x x Input Cooling ceiling valve Room 1 001 5 001 1 bit 1 byte x x x x Input Cooling ceiling dew point alarm sensor Room 9 001 2 bytes x x x x ...

Page 205: ...thermostat master The data point type for the group object is dependent on the settings in the module If the Display set slave DPT 9 001 DPT 9 002 option is selected for the Room setpoint temperature parameter and the Absolute setpoint temperatures option is selected for the Room setpoint temperature type parameter DPT 9 001 Signal value 273 670760 C An absolute setpoint adjustment is transmitted ...

Page 206: ...273 670760 C An absolute setpoint adjustment is transmitted e g 22 C If the Display set slave DPT 9 001 DPT 9 002 option is selected for the Room setpoint temperature parameter and the Relative setpoint temperatures option is selected for the Room setpoint temperature type parameter DPT 9 002 Signal value 67760 670760 K A relative setpoint adjustment is transmitted e g 2 K If the Display set slave...

Page 207: ... Telegram value 0 Off 1 On Output On Off request slave Room 1 bit DPT 1 001 C T The module has this group object if the Display set slave option is selected for the Controller On Off parameter This group object is used for synchronization between the Room ASM slave and the room thermostat master For this purpose the group object must be connected to the controller s master s group object of the sa...

Page 208: ... the changeover request to the controller in this group object Telegram value 0 Cooling 1 Heating Input Operating mode Room 1 byte DPT 20 102 C W T U The module has this group object if the Display option is selected for the Operating mode parameter Input for the connection of the operating mode from the room thermostat Telegram value 0 Auto 1 Comfort 2 Standby 3 Economy 4 Building Protection Inpu...

Page 209: ... 3 Economy 4 Building Protection Input Operating mode override slave Room 1 byte DPT 20 102 C W T U The module has this group object if the Display set slave option is selected for the Operating mode parameter This group object is used for synchronization of the overridden operating mode between the Room ASM slave and the room thermostat master For this purpose the group object must be connected t...

Page 210: ...he Yes option is selected for the Rel humidity parameter Input for the connection of the relative humidity from the sensor Telegram value 0 100 Input CO2 value Room 2 bytes DPT 9 008 C W T U The module has this group object if the Yes option is selected for the CO2 value parameter Input for the connection of the CO2 value from the air quality sensor Telegram value 0 670760 Input Fan coil unit valv...

Page 211: ...or either heating or cooling depending on the heating cooling operating type Telegram value 0 100 Input Fan coil unit fan speed Room 1 byte DPT 5 001 C W T U The module has this group object if any option except None is selected for the Fan coil unit parameter and the Display option is selected for the Fan coil unit fan speed parameter Input for the fan speed on the fan coil unit Telegram value 0 ...

Page 212: ...d e g 50 Fan speeds are converted into the corresponding percentage If any option except None is selected for the Fan coil unit parameter and the Display set slave DPT 5 010 option is selected for the Fan coil unit fan speed parameter DPT 5 010 Telegram value 0 5 The fan speed is transmitted Input Fan coil unit fan manual confirm slave Room 1 bit DPT 1 011 C W T U The module has this group object ...

Page 213: ...value 0 100 The fan speed in percent is transmitted e g 50 Fan speeds are converted into the corresponding percentage If any option except None is selected for the Fan coil unit parameter and the Display set slave DPT 5 010 option is selected for the Fan coil unit fan speed parameter DPT 5 010 Telegram value 0 5 The fan speed is transmitted Output Request fan manually slave Room 1 bit DPT 1 011 C ...

Page 214: ... value 0 100 Input Fan coil unit fresh air damper Room 1 bit DPT 1 019 1 byte DPT 5 001 C W T U Input for the position of the fresh air damper The data point type for the group object is dependent on the settings in the module If any option except None is selected for the Fan coil unit parameter and the Open Closed option is selected for the Fan coil unit fresh air damper parameter DPT 1 019 Teleg...

Page 215: ...or the position control value of the radiator valve The data point type for the group object is dependent on the settings in the module If the On Off option is selected for the Radiator parameter DPT 1 001 Telegram value 0 Off 1 On If the 0 100 option is selected for the Radiator parameter DPT 5 001 Telegram value 0 100 Input Floor heating valve Room 1 bit DPT 1 001 1 byte DPT 5 001 C W T U Input ...

Page 216: ...n the settings in the module If the On Off option is selected for the Cooling ceiling parameter DPT 1 001 Telegram value 0 Off 1 On If the 0 100 option is selected for the Cooling ceiling parameter DPT 5 001 Telegram value 0 100 Input Cooling ceiling dew point alarm sensor Room 2 bytes DPT 9 001 C W T U The module has this group object if the On Off option or the 0 100 option is selected for the C...

Page 217: ...he split unit Telegram value 0 100 Input Split unit status Room 1 byte DPT 20 105 C W T U The module has this group object if the Yes option is selected for the Split unit parameter Input for the status of the split unit Telegram value 0 Auto 1 Heat 2 Morning Warmup 3 Cool 4 Night Purge 5 Precool 6 Off 7 Test 8 Emergency Heat 9 Fan only 0A Free Cool 0B Ice 0C Maximum Heat Mode 0D Economic Heat Coo...

Page 218: ...alve cooling Analog value 98 1 0 Output Room Fan coil unit valve Analog value 98 1 0 Output Room Fan coil unit fan speed Analog value 98 1 0 Output Room Fan coil unit fan manual Binary value Output Room Fan coil unit additional stage heating Binary value Analog value 98 1 0 Output Room Fan coil unit fresh air damper Binary value Analog value 98 1 0 Output Room Fan coil unit dew point sensor Binary...

Page 219: ...ve option is selected for the Controller On Off parameter Outputs whether the room thermostat is switched on or off Signal value 0 Off 1 On Room Heating cooling operating type Binary value The module has this BACnet output object if any option except None is selected for the Heating cooling operating type parameter Outputs the current heating cooling operating type Signal value 0 Cooling 1 Heating...

Page 220: ...2 Standby 3 Economy 4 Building Protection Room Window status Binary value The module has this BACnet output object if the Yes option is selected for the Window status parameter Outputs the window status Signal value 0 Closed 1 Open Room Presence slave Binary value The module has this BACnet output object if the Yes option is selected for the Presence detector parameter Outputs the presence status ...

Page 221: ...lve cooling Analog value 98 1 0 The module has this BACnet output object if the 2 pipe cooling option or the 4 pipe heating cooling option is selected for the Fan coil unit parameter Outputs the valve position control value on the fan coil unit for cooling Signal value 0 100 Room Fan coil unit valve Analog value 98 1 0 The module has this BACnet output object if the 2 pipe heating cooling option i...

Page 222: ...al stage heating parameter Object type binary value Unit Send condition Signal value 0 Off 1 On If any option except None is selected for the Fan coil unit parameter and the 0 100 option is selected for the Fan coil unit additional stage heating parameter Object type analog value Unit 98 Send condition 1 0 Signal value 0 100 Room Fan coil unit fresh air damper Binary value Analog value 98 1 0 Outp...

Page 223: ... has this BACnet output object if any option except None is selected for the Fan coil unit parameter and the Yes option is selected for the Fan coil unit level sensor parameter Outputs the signal value from the level sensor in the fan coil unit Signal value 0 Off 1 On Room Radiator valve Binary value Analog value 98 1 0 Outputs the position of the radiator valve The object type for the object is d...

Page 224: ...om Floor temperature sensor Analog value C 62 1 0 The module has this BACnet output object if the On Off option or the 0 100 option is selected for the Floor heating parameter and the Yes option is selected for the Floor temperature sensor parameter Outputs the floor temperature Signal value 273 670760 C Room Cooling ceiling valve Binary value Analog value 98 1 0 Outputs the position of the coolin...

Page 225: ...ing dew point alarm sensor parameter Outputs the signal value from the dew point sensor in the cooling ceiling Signal value 273 670760 C Room Split unit On Off Binary value The module has this BACnet output object if the Yes option is selected for the Split unit parameter Outputs the operating status of the split unit Signal value 0 Off 1 On Room Split unit fan speed Analog value 98 1 0 Outputs th...

Page 226: ...the split unit The module has this BACnet output object if the Yes option is selected for the Split unit parameter Signal value 0 Auto 1 Heat 2 Morning Warmup 3 Cool 4 Night Purge 5 Precool 6 Off 7 Test 8 Emergency Heat 9 Fan only 0A Free Cool 0B Ice 0C Maximum Heat Mode 0D Economic Heat Cool Mode 0E Dehumidification 0F Calibration Mode 10 Emergency Cool Mode 11 Emergency Steam Mode 14 No Dem ...

Page 227: ...ABB i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 227 7 7 6 WebUI Open the detailed view of the ASM by clicking the ASM s tile ...

Page 228: ...tions not activated are hidden If activated in the settings for the module all users except the Viewer can operate the systems via the web user interface and e g change the room setpoint temperature or override a valve If values are changed the new value is only displayed once the KNX room thermostat linked has updated this value Depending on the layout and load on the KNX system there may be a sh...

Page 229: ...he application controller outputs the room setpoint temperatures set on the KNX bus on the ASM output socket and on BACnet If the values are linked to several controllers at the same time these values can apply to several rooms The operating modes for which the setpoint temperatures can be set via the web user interface can be changed in the parameters for the module The module has a validation fu...

Page 230: ...i bus KNX Parameters 230 2CDC508198D0211 Rev A AC S 1 x 1 7 8 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM settings ...

Page 231: ...played A group object is displayed A BACnet object is displayed Cooling Building Protection Options No checkbox cleared Yes checkbox selected Cooling Economy Options No checkbox cleared Yes checkbox selected Cooling Standby Options No checkbox cleared Yes checkbox selected Cooling Comfort Options No checkbox cleared Yes checkbox selected Heating Comfort Options No checkbox cleared Yes checkbox sel...

Page 232: ... change continuously between heating and cooling If only heating or only cooing is activated this setting has no effect If the dead zone is set to 0 C this function is deactivated The dead zone cannot be set via the web user interface Send cyclically values to KNX every Options 00 10 00 06 00 00 23 59 00 hh mm ss The room setpoint temperatures are sent immediately on the KNX bus after every change...

Page 233: ...ther the following sequence is maintained 4 Cooling Building Protection 5 Cooling Economy 6 Cooling Standby 7 Cooling Comfort 8 Dead band 9 Heating Comfort 10 Heating Standby 11 Heating Economy 12 Heating Building Protection Every room setpoint temperature must equal to or greater than the previous Furthermore the dead band set must be respected Otherwise the incorrect fields are marked with a red...

Page 234: ...hich the checkbox in the Interfaces parameter has not been cleared Overview of the ASM sockets for linking to other modules Type Object name Data type Output Cooling Building Protection 9 001 Output Cooling Economy 9 001 Output Cooling Standby 9 001 Output Cooling Comfort 9 001 Output Heating Comfort 9 001 Output Heating Standby 9 001 Output Heating Economy 9 001 Output Heating Building Protection...

Page 235: ...0 50 C Cooling Comfort DPT 9 001 The module has this output socket if the Yes option is selected for the Cooling Comfort parameter Signal value 0 50 C Heating Comfort DPT 9 001 The module has this output socket if the Yes option is selected for the Heating Comfort parameter Signal value 0 50 C Heating Standby DPT 9 001 The module has this output socket if the Yes option is selected for the Heating...

Page 236: ...int temperatures 9 001 2 bytes x x x Object function Name can be changed separately Data type Flags Output Cooling Building Protection Room setpoint temperatures 2 bytes DPT 9 001 C R T The module has this output group object if the Yes option is selected for the Cooling Building Protection parameter Telegram value 0 50 C Output Cooling Economy Room setpoint temperatures 2 bytes DPT 9 001 C R T Th...

Page 237: ...s 2 bytes DPT 9 001 C R T The module has this output group object if the Yes option is selected for the Heating Standby parameter Telegram value 0 50 C Output Heating Economy Room setpoint temperatures 2 bytes DPT 9 001 C R T The module has this output group object if the Yes option is selected for the Heating Economy parameter Telegram value 0 50 C Output Heating Building Protection Room setpoint...

Page 238: ...Output Room setpoint temperatures Cooling Building Protection Analog value C 62 1 0 Output Room setpoint temperatures Cooling Standby Analog value C 62 1 0 Output Room setpoint temperatures Heating Comfort Analog value C 62 1 0 Output Room setpoint temperatures Heating Economy Analog value C 62 1 0 Output Room setpoint temperatures Heating Building Protection Analog value C 62 1 0 Output Room setp...

Page 239: ...res Cooling Standby Analog value C 62 1 0 The module has this BACnet output object if the Yes option is selected for the Cooling Standby parameter Signal value 0 50 C Room setpoint temperatures Heating Comfort Analog value C 62 1 0 The module has this BACnet output object if the Yes option is selected for the Heating Comfort parameter Signal value 0 50 C Room setpoint temperatures Heating Economy ...

Page 240: ...ABB i bus KNX Parameters 240 2CDC508198D0211 Rev A AC S 1 x 1 7 8 6 WebUI Open the detailed view of the ASM by clicking the ASM s tile ...

Page 241: ...the Viewer have the right to change these values The room setpoint temperatures can be set in the range from 0 C 50 C A validation process makes sure only the following sequence can be set 1 Cooling Building Protection 2 Cooling Economy 3 Cooling Standby 4 Cooling Comfort 5 Dead band 6 Heating Comfort 7 Heating Standby 8 Heating Economy 9 Heating Building Protection Every room setpoint temperature...

Page 242: ...ion specific automation module ASM calculates the supply setpoint temperature and sends the value calculated to a heating distribution circuit controller heating circuit controller The module also permits the display and operation via the module s web user interface of the heating distribution circuit controller linked via KNX ...

Page 243: ...i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 243 7 9 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM settings ...

Page 244: ...pply setpoint temperature source Options ASM input socket WebUI Input BACnet input object Calculated weather compensated This parameter determines how the supply setpoint temperature is determined for the heating distribution circuit This setpoint is sent to the heating distribution circuit controller via the group object ASM input socket The supply setpoint temperature received via the input sock...

Page 245: ...o the supply setpoint temperature and is limited by the Max supply temperature parameter Selection of WebUI Input or BACnet input object option Dependent parameter s Initial values Supply setpoint temperature Options 0 80 100 C This parameter defines the supply setpoint temperature that is output after downloading the module This value is output until a new value is entered on the web user interfa...

Page 246: ...and are based on the design point The heating curve can be seen on the web user interface for the module The values for the curve cannot be changed directly Custom The shape of the curve can be set as required by entering the points Selection of Heating curve option Dependent parameter s Nominal outside temperature Options 100 14 100 C The outside temperature at the design point is specified using...

Page 247: ... 0 60 100 C The theoretical return temperature at the design point is specified using this parameter This information provides the spread between the supply and return temperature This information is used to calculate the heating curve Max supply temperature Options 0 80 100 C The supply setpoint temperature output by the module is limited using this parameter This is a safety function that ensure...

Page 248: ...e radiator exponent describes the relationship between the increasing supply temperature and the non proportionally increasing heat dissipation into the room This information is used to calculate the heating curve The higher this value is the more curved the heating curve is Start supply temperature curve at outside temperature Options 100 19 100 C The outside temperature at which heating is start...

Page 249: ...ting curve Based on Scheduler The heating curve is adjusted dynamically based on a scheduler The scheduler switches between the operating modes and the related room setpoint temperatures A heating curve is displayed for each operating mode and the mode activated is marked on the web user interface for the module An ASM input socket for connecting an operating mode scheduler is displayed on activat...

Page 250: ...rameter and a corresponding ASM input socket displayed Scheduler operating mode Economy Options No checkbox cleared Yes checkbox selected The Economy operating mode is activated using this parameter and a corresponding ASM input socket displayed Scheduler operating mode Building Protection Options No checkbox cleared Yes checkbox selected The Building Protection operating mode is activated using t...

Page 251: ...w opens where you can add a custom supply temperature curve by changing the supply setpoint temperature The shape of the curve can be set as required by entering the points The limit specified via the Max supply temperature parameter is displayed on the chart as a red line This curve is used after downloading the module and can be modified via the web user interface for the module ...

Page 252: ...this way during times with low heat demand in the rooms the heat provided is reduced to lower the losses and therefore save energy On the other hand in times with increased heat demand from the rooms the amount of heat provided is increased In this way the required comfort temperature is reached more quickly in the rooms The current heat demand from the rooms is determined by evaluating the contro...

Page 253: ...ds to be observed and optimized over several weeks Selection of Yes option Dependent parameter s Increase supply temperature Options 0 10 100 K This parameter specifies the maximum value up to which the supply setpoint temperature is allowed to be increased by the Room involvement function This increase relates to the value specified by the heating curve A value of 0 K deactivates the increase by ...

Page 254: ...value set the faster the control reacts However the value should not be selected too small because otherwise there may be a risk of overshoot Example The value Xp 30 means If the highest control value on the ASM input socket is 30 below the Optimum room control value the supply temperature increases by the full value of Increase supply temperature Room involvement calculation delay Options 00 00 0...

Page 255: ...This function is affected by the Enable heating distribution circuit control based on ASM input socket function If both functions are activated the Enable heating distribution circuit control based on ASM input socket has a higher priority Selection of Yes option Dependent parameter s Switch on if the room demand is higher than Options 0 10 100 The module sends a switch on command to the heating d...

Page 256: ...e of this object is forwarded to the heating distribution circuit controller via a group object that is then displayed If the Switch off if no room demand function is also activated there is the following relationship ASM input socket Control On Off Heating cooling distribution circuit controller control Result of the Switch off if no room demand function Result and output in the Control On Off gr...

Page 257: ...are adjusted to suit the setting Override by WebUI Options No checkbox cleared Yes checkbox selected If this function is activated the pump can be overridden via the web user interface For this purpose additional group objects are displayed that must be connected to the heating distribution circuit controller Pump display operating status Options No checkbox cleared Yes checkbox selected If the pu...

Page 258: ...put on the web user interface in a BACnet object and on the ASM socket The ASM only displays this state there are no switching actions based on the fault status Display pump repair switch status Options No checkbox cleared Yes checkbox selected If the pump has a repair switch and the contact position is output this status can be received by a group object via this function and output on the web us...

Page 259: ...lve option Dependent parameter s Status Valve purge Options No checkbox cleared Yes checkbox selected If this function is activated the status of the valve purge can be received by a group object and output on the web user interface in a BACnet object and on the ASM socket Valve override disable enable Options No checkbox cleared Yes checkbox selected If this function is activated the valve can be...

Page 260: ...trol value 5 001 Output Supply temperature 9 001 Output Return temperature 9 001 Output Control On Off 1 001 Output Valve override disable enable 1 003 Output Valve override control value 5 001 Output Status Valve purge 1 011 Output Pump A operating status Off On 1 011 Output Pump A relay status 1 001 Output Pump A fault 1 005 Output Pump A repair switch status 1 011 Output Pump A override disable...

Page 261: ... input socket if the Yes option is selected for the Supply temperature control parameter and the ASM input socket option is selected for the Supply setpoint temperature source parameter Specification of the supply setpoint temperature by another module This value is output in the corresponding group objects to the heating distribution circuit controller linked Note The value can be affected by the...

Page 262: ...refore the supply setpoint temperature to the current needs Signal value 273 670760 C Room setpoint temperature Economy DPT 9 001 This module has this input socket if the Yes option is selected for the Supply temperature control parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source parameter the Based on Scheduler option is selected for the Econ...

Page 263: ...parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source parameter and the Based on the current room setpoint temperatures option is selected for the Economy mode parameter Input for the current heating room setpoint temperatures for all rooms connected to the heating distribution circuit The module selects the highest value and uses this value for...

Page 264: ...273 670760 C Return temperature DPT 9 001 Outputs the current return temperature that is received via the related group object Signal value 273 670760 C Control On Off DPT 1 001 The module has this output socket in the following conditions If the Yes option is selected for the Supply temperature control parameter and the Yes option is selected for the Enable heating distribution circuit control ba...

Page 265: ...Signal value 0 100 Status Valve purge DPT 1 011 The module has this output socket if the 3 way valve mixing valve option or the 2 way valve option is selected for the Valve type parameter and the Yes option is selected for the Status Valve purge parameter Outputs the status as to whether the heating distribution circuit controller is actually undertaking a valve purge This value is received from t...

Page 266: ...tch status parameter Outputs the contact position provided by the pump repair switch Signal value 0 Inactive 1 Active Pump A override disable enable DPT 1 003 The module has this output socket if the Yes option is selected for the Override by WebUI parameter Outputs whether the heating distribution circuit s pump is overridden Signal value 0 Disabled 1 Enabled Pump A override value DPT 1 001 The m...

Page 267: ...output socket if the Yes option is selected for the Double pump parameter Outputs the status of the second pump from the heating distribution circuit controller Signal value 0 Off 1 On Pump B fault DPT 1 005 The module has this output socket if the Yes option is selected for the Double pump parameter and the Yes option is selected for the Pump display pump fault status parameter Outputs the fault ...

Page 268: ...on is selected for the Supply temperature control parameter Outputs the current supply setpoint temperature as is sent by the module to the heating distribution circuit controller via the related group object The supply setpoint temperature output here is depending on the setting either calculated by this module based on the outside temperature or specified via an ASM input socket or BACnet and al...

Page 269: ...upply setpoint temperature is increased or reduced by the Room involvement function Signal value 670760 670760 K Max room setpoint temperature DPT 9 001 This module has this output socket if the Yes option is selected for the Supply temperature control parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source parameter and the Based on the current r...

Page 270: ...ion circuit 1 011 1 bit x x x Input Pump A repair switch status Heating distribution circuit 1 011 1 bit x x x Input Pump A fault Heating distribution circuit 1 011 1 bit x x x Input Pump A operating status Off On Heating distribution circuit 1 011 1 bit x x x In Output Pump A override disable enable Heating distribution circuit 1 003 1 bit x x x x In Output Pump A override value Heating distribut...

Page 271: ...T Input for supply temperature measured in the heating distribution circuit Telegram value 273 670760 C Input Return temperature Heating distribution circuit 2 bytes DPT 9 001 C W T Input for return temperature measured in the heating distribution circuit Telegram value 273 670760 C Output Supply setpoint temperature Heating distribution circuit 2 bytes DPT 9 001 C R T Outputs the supply setpoint ...

Page 272: ...Yes option is selected for the Valve override disable enable parameter This object specifies the control value valve position used to override the valve for the heating distribution circuit if the valve override is active Telegram value 0 100 Input Status Valve purge Heating distribution circuit 1 bit DPT 1 011 C W T The module has this group object if the 3 way valve mixing valve option or the 2 ...

Page 273: ...Off On provided by the pump On pumps with their own control this operating status can differ from the operating status of the heating distribution circuit controller Telegram value 0 Inactive 1 Active In Output Pump A override disable enable Heating distribution circuit 1 bit DPT 1 003 C R W T The module has this group object if the Yes option is selected for the Override by WebUI parameter This o...

Page 274: ...object activates deactivates the second pump override for the heating distribution circuit controller Telegram value 0 Disabled 1 Enabled In Output Pump B override value Heating distribution circuit 1 bit DPT 1 001 C R W T The module has this group object if the Yes option is selected for the Double pump parameter and the Yes option is selected for the Override by WebUI parameter This object speci...

Page 275: ...ump B relay status Heating distribution circuit 1 bit DPT 1 001 C W T The module has this group object if the Yes option is selected for the Double pump parameter Input for the status of the second pump from the heating distribution circuit controller Telegram value 0 Off 1 On Output Control On Off Heating distribution circuit 1 bit DPT 1 001 C R T The module has this group object in the following...

Page 276: ...log value C 62 1 0 Output Heating distribution circuit Control On Off Binary value Output Heating distribution circuit Room involvement Analog value C 62 1 0 Output Heating distribution circuit Control On Off override disable enable Binary value Output Heating distribution circuit Room control values Analog value 98 1 0 Output Heating distribution circuit Pump A override disable enable Binary valu...

Page 277: ...distribution circuit Return temperature Analog value C 62 1 0 Outputs the current return temperature that is received via the related group object Signal value 273 670760 C Heating distribution circuit Supply temperature Analog value C 62 1 0 Outputs the current supply temperature that is received via the related group object Signal value 273 670760 C Heating distribution circuit Supply setpoint t...

Page 278: ... the web user interface Signal value 0 Not overridden 1 Overridden Heating distribution circuit Supply setpoint temperature External specification Analog value C 62 1 0 This module has this BACnet input object if the Yes option is selected for the Supply temperature control parameter and the ASM input socket option is selected for the Supply setpoint temperature source parameter Outputs the supply...

Page 279: ...ure in the Standby operating mode if this operating mode is active Signal value 273 670760 C Heating distribution circuit Room setpoint temperature Economy Analog value C 62 1 0 This module has this BACnet output object if the Yes option is selected for the Supply temperature control parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source paramete...

Page 280: ...ntrol parameter and the Yes option is selected for the Enable heating distribution circuit control based on ASM input socket parameter If the Yes option is selected for the Switch off if no room demand parameter Outputs the status Off On of the control that is sent to the heating distribution circuit controller via the related group object The state is dependent on the Enable heating distribution ...

Page 281: ...e Supply temperature control parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source parameter and the Yes option is selected for the Room involvement parameter If the Yes option is selected for the Switch off if no room demand parameter Outputs the highest room setpoint temperature that is present on the ASM input socket and that is used by the E...

Page 282: ...e 1 Active Heating distribution circuit Pump A relay status Binary value Outputs the status of the pump from the heating distribution circuit controller Signal value 0 Off 1 On Heating distribution circuit Pump A fault Binary value The module has this BACnet output object if the Yes option is selected for the Pump display pump fault status parameter Outputs the fault status provided by the pump Si...

Page 283: ...specifies the state with which the heating distribution circuit s second pump is overridden if the pump override is active Signal value 0 Off 1 On Heating distribution circuit Pump B operating status Off On Binary value The module has this BACnet output object if the Yes option is selected for the Double pump parameter and the Yes option is selected for the Pump display operating status parameter ...

Page 284: ...ovided by the second pump repair switch Signal value 0 Inactive 1 Active Heating distribution circuit Valve control value Analog value 98 1 0 The module has this BACnet output object if the 3 way valve mixing valve option or the 2 way valve option is selected for the Valve type parameter Outputs the valve control value for the heating distribution circuit This value is received from the heating di...

Page 285: ... to override the heating distribution circuit s valve if the override is active Signal value 0 100 Heating distribution circuit Status Valve purge Binary value The module has this BACnet output object if the 3 way valve mixing valve option or the 2 way valve option is selected for the Valve type parameter and the Yes option is selected for the Status Valve purge parameter Outputs the status as to ...

Page 286: ... section shows the current operating status of the heating distribution circuit controller linked via KNX If activated in the settings the control by the heating distribution circuit controller can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to one of the two Override positions The current state of the heating distribution circ...

Page 287: ...odule This temperature is sent via KNX to the heating distribution circuit controller linked If activated in the settings the supply setpoint temperature can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to the Override position A supply setpoint temperature continues to be calculated and displayed in Auto during the override In ...

Page 288: ... controller can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to one of the two Override positions Status Pump relay Outputs the status of the pump from the heating distribution circuit controller linked Pump operating status Outputs the operating status Off On provided by the pump On pumps with their own control this operating s...

Page 289: ... It is also indicated whether a valve purge is in progress If activated in the settings the valve position can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to the Override position The status sent by the heating distribution circuit controller continues to be displayed in Auto during the override ...

Page 290: ...ture is calculated The settings on which the calculation is based can be changed The information displayed on this page may vary depending on which settings have been selected for the supply setpoint temperature calculation in the ASM settings This section shows the current status of the calculation These values cannot be changed by the user ...

Page 291: ... rooms connected to the heating distribution circuit This value is used by the Room involvement function Max room control value Outputs the highest heating control values valve positions for all rooms connected to the heating distribution circuit The value is used by the Room involvement function to adjust the heating curve and therefore the supply setpoint temperature to the current needs This va...

Page 292: ...us so that the settings can be adapted to the local situation during the operating of the system without renewed ETS programming The settings on the web user interface always apply The parameters set in the ASM settings are overwritten and only become active again on the reinstallation of the ASM You will find the description of the ASM settings in the chapter 7 15 2 Settings ...

Page 293: ...nctions Custom heating curve chart If the supply setpoint temperature is calculated based on the weather and in the ASM settings the Custom option is selected for the Calculation formula parameter you can change the curve on the web user interface by specifying the points The points from the ASM settings parameterized are used as the initial values The settings on the web user interface always app...

Page 294: ... ASM 7 10 1 General This application specific automation module ASM calculates the supply setpoint temperature and sends the value calculated to a heat generator linked via KNX The module also allows the heat generator to be displayed and operated via the module s web user interface ...

Page 295: ...i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 295 7 10 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM settings ...

Page 296: ...emand function Result and output in the Heat generator On Off group object Off Switched off Off On Switched off On Off Switched on Off On Switched on On Show operating status Options No checkbox cleared Yes checkbox selected If the heat generator outputs its operating status Off On this status can be received by a group object via this function and output on the web user interface in a BACnet obje...

Page 297: ...erature source Options ASM input socket WebUI Input BACnet input object Calculated weather compensated This parameter determines how the supply setpoint temperature is determined for the heat generator This setpoint is sent to the heat generator via the group object ASM input socket The supply setpoint temperature received via the input socket on the ASM is used This is an ASM multiple socket on w...

Page 298: ...o the supply setpoint temperature and is limited by the Max supply temperature parameter Selection of WebUI Input or BACnet input object option Dependent parameter s Initial values Supply setpoint temperature Options 0 80 100 C This parameter defines the supply setpoint temperature that is output after downloading the module This value is output until a new value is entered on the web user interfa...

Page 299: ...and are based on the design point The heating curve can be seen on the web user interface for the module The values for the curve cannot be changed directly Custom The shape of the curve can be set as required by entering the points Selection of Heating curve option Dependent parameter s Nominal outside temperature Options 100 14 100 C The outside temperature at the design point is specified using...

Page 300: ... 0 60 100 C The theoretical return temperature at the design point is specified using this parameter This information provides the spread between the supply and return temperature This information is used to calculate the heating curve Max supply temperature Options 0 80 100 C The supply setpoint temperature output by the module is limited using this parameter This is a safety function that ensure...

Page 301: ...e radiator exponent describes the relationship between the increasing supply temperature and the non proportionally increasing heat dissipation into the room This information is used to calculate the heating curve The higher this value is the more curved the heating curve is Start supply temperature curve at outside temperature Options 100 19 100 C The outside temperature at which heating is start...

Page 302: ...ting curve Based on Scheduler The heating curve is adjusted dynamically based on a scheduler The scheduler switches between the operating modes and the related room setpoint temperatures A heating curve is displayed for each operating mode and the mode activated is marked on the web user interface for the module An ASM input socket for connecting an operating mode scheduler is displayed on activat...

Page 303: ...rameter and a corresponding ASM input socket displayed Scheduler operating mode Economy Options No checkbox cleared Yes checkbox selected The Economy operating mode is activated using this parameter and a corresponding ASM input socket displayed Scheduler operating mode Building Protection Options No checkbox cleared Yes checkbox selected The Building Protection operating mode is activated using t...

Page 304: ...w opens where you can add a custom supply temperature curve by changing the supply setpoint temperature The shape of the curve can be set as required by entering the points The limit specified via the Max supply temperature parameter is displayed on the chart as a red line This curve is used after downloading the module and can be modified via the web user interface for the module ...

Page 305: ...y during times with low heat demand in the rooms the heat provided is reduced to lower the losses and therefore save energy On the other hand in times with increased heat demand from the rooms the amount of heat provided is increased In this way the required comfort temperature is reached more quickly in the rooms The current heat demand from the rooms is determined by evaluating the control value...

Page 306: ...nd optimized over several weeks Selection of Yes option Dependent parameter s Increase supply temperature Options 0 10 100 K This parameter specifies the maximum value up to which the supply setpoint temperature is allowed to be increased by the Room involvement function This increase relates to the value specified by the heating curve A value of 0 K deactivates the increase by the room involvemen...

Page 307: ...value set the faster the control reacts However the value should not be selected too small because otherwise there may be a risk of overshoot Example The value Xp 30 means If the highest control value on the ASM input socket is 30 below the Optimum room control value the supply temperature increases by the full value of Increase supply temperature Room involvement calculation delay Options 00 00 0...

Page 308: ...n the heating system This function is affected by the Enable heat generator based on ASM input socket function If both functions are activated the Enable heat generator based on ASM input socket has a higher priority Selection of Yes option Dependent parameter s Switch on if the room demand is higher than Options 0 10 100 The module sends a switch on command to the heat generator if the highest ro...

Page 309: ... the setting Override by WebUI Options No checkbox cleared Yes checkbox selected If this function is activated the pump can be overridden via the web user interface For this purpose additional group objects are displayed that must be connected to the heat generator s pump Pump display operating status Options No checkbox cleared Yes checkbox selected If the pump outputs its operating status Off On...

Page 310: ...put on the web user interface in a BACnet object and on the ASM socket The ASM only displays this state there are no switching actions based on the fault status Display pump repair switch status Options No checkbox cleared Yes checkbox selected If the pump has a repair switch and the contact position is output this status can be received by a group object via this function and output on the web us...

Page 311: ...ction 9 001 Input Room control values 5 001 Input Room setpoint temperature 9 001 Input Operating mode 20 102 Output Supply temperature 9 001 Output Return temperature 9 001 Output Heat generator On Off 1 001 Output Pump operating status Off On 1 011 Output Pump relay status 1 001 Output Pump fault 1 005 Output Pump repair switch status 1 011 Output Pump override disable enable 1 003 Output Pump o...

Page 312: ...selected for the Supply temperature control parameter and the ASM input socket option is selected for the Supply setpoint temperature source parameter Specification of the supply setpoint temperature by another module This value is output in the corresponding group objects to the heat generator linked Note The value can be affected by the Max supply temperature and Supply setpoint temperature offs...

Page 313: ...refore the supply setpoint temperature to the current needs Signal value 273 670760 C Room setpoint temperature Economy DPT 9 001 This module has this input socket if the Yes option is selected for the Supply temperature control parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source parameter the Based on Scheduler option is selected for the Econ...

Page 314: ...trol parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source parameter and the Based on the current room setpoint temperatures option is selected for the Economy mode parameter Input for the current heating room setpoint temperatures for all rooms connected to the heating system The module selects the highest value and uses this value for the Econ...

Page 315: ...SM input socket parameter If the Yes option is selected for the Switch off if no room demand parameter Outputs the on off status of the heat generator that is sent to the heat generator via the related group object The state is dependent on the Enable heat generator based on ASM input socket and Switch off if no room demand parameters Signal value 0 Off 1 On Pump operating status Off On DPT 1 011 ...

Page 316: ...mp is overridden if the pump override is active Signal value 0 Off 1 On Supply setpoint temperature DPT 9 001 The module has this output socket if the Yes option is selected for the Supply temperature control parameter Outputs the current supply setpoint temperature as is sent by the module to the heat generator via the related group object The supply setpoint temperature output here is depending ...

Page 317: ...sated option is selected for the Supply setpoint temperature source parameter and the Based on the current room setpoint temperatures option is selected for the Economy mode parameter Outputs the highest room setpoint temperature that is present on the ASM input socket and that is used by the Economy mode function Signal value 273 670760 C Heat generator operating status DPT 1 001 The module has t...

Page 318: ...ump relay status Heat generator 1 001 1 bit x x x Output Heat generator On Off Heat generator 1 001 1 bit x x x Input Heat generator operating status Heat generator 1 011 1 bit x x x Input Heat generator failure status Heat generator 1 011 1 bit x x x In Output Pump override disable enable Heat generator 1 003 1 bit x x x x In Output Pump override value Heat generator 1 001 1 bit x x x x Input Pum...

Page 319: ...y the module as the value specified to the heat generator Telegram value 273 670760 C Input Pump relay status Heat generator 1 bit DPT 1 001 C W T The module has this group object if the Yes option is selected for the Pump parameter Input for the status of the heat generator s pump Telegram value 0 Off 1 On Output Heat generator On Off Heat generator 1 bit DPT 1 001 C R T The module has this group...

Page 320: ...1 011 C W T The module has this group object if the Yes option is selected for the Show fault status parameter Input for the fault status provided by the heat generator Signal value 0 Inactive 1 Active In Output Pump override disable enable Heat generator 1 bit DPT 1 003 C R W T The module has this group object if the Yes option is selected for the Override by WebUI parameter This object activates...

Page 321: ...Telegram value 0 Inactive 1 Active Input Pump fault Heat generator 1 bit DPT 1 011 C W T The module has this group object if the Yes option is selected for the Pump display pump fault status parameter Input for the fault status provided by the pump Telegram value 0 Inactive 1 Active Input Pump repair switch status Heat generator 1 bit DPT 1 011 C W T The module has this group object if the Yes opt...

Page 322: ...generator Room setpoint temperature Standby Analog value C 62 1 0 Output Heat generator Room setpoint temperature Economy Analog value C 62 1 0 Output Heat generator Room setpoint temperature Building Protection Analog value C 62 1 0 Output Heat generator Max room setpoint temperature Analog value C 62 1 0 Output Heat generator Heat generator On Off Binary value Output Heat generator Room involvem...

Page 323: ...ition Heat generator Return temperature Analog value C 62 1 0 Outputs the current return temperature that is received via the related group object Signal value 273 670760 C Heat generator Supply temperature Analog value C 62 1 0 Outputs the current supply temperature that is received via the related group object Signal value 273 670760 C Heat generator Supply setpoint temperature status Analog val...

Page 324: ... the web user interface Signal value 0 Not overridden 1 Overridden Heat generator Supply setpoint temperature External specification Analog value C 62 1 0 This module has this BACnet input object if the Yes option is selected for the Supply temperature control parameter and the ASM input socket option is selected for the Supply setpoint temperature source parameter Outputs the supply setpoint temp...

Page 325: ...ure in the Standby operating mode if this operating mode is active Signal value 273 670760 C Heat generator Room setpoint temperature Economy Analog value C 62 1 0 This module has this BACnet output object if the Yes option is selected for the Supply temperature control parameter the Calculated weather compensated option is selected for the Supply setpoint temperature source parameter the Based on...

Page 326: ... for the Supply temperature control parameter and the Yes option is selected for the Enable heat generator based on ASM input socket parameter If the Yes option is selected for the Switch off if no room demand parameter Outputs the on off status of the heat generator that is sent to the heat generator via the related group object The state is dependent on the Enable heat generator based on ASM inp...

Page 327: ... heat generator Due to the control integrated into the heat generator this status may differ from the operating status specified by this module Signal value 0 Off 1 On Heat generator Heat generator failure status Binary value The module has this BACnet output object if the Yes option is selected for the Show fault status parameter Outputs the fault status provided by the heat generator Signal valu...

Page 328: ...lected for the Override by WebUI parameter This object specifies the state with which the heat generator s pump is overridden if the pump override is active Signal value 0 Off 1 On Heat generator Pump operating status Off On Binary value The module has this BACnet output object if the Yes option is selected for the Pump display operating status parameter Outputs the operating status Off On provide...

Page 329: ... selected for the Pump display pump fault status parameter Outputs the fault status provided by the pump Signal value 0 Inactive 1 Active Heat generator Pump repair switch status Binary value The module has this BACnet output object if the Yes option is selected for the Display pump repair switch status parameter Outputs the contact position provided by the pump repair switch Signal value 0 Inacti...

Page 330: ...l sections Heat generator page This section shows the current operating status of the heat generator linked via KNX If activated in the settings the control by the heat generator can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to one of the two Override positions The current state of the heat generator continues to be displayed...

Page 331: ...odule This temperature is sent via KNX to the heat generator linked If activated in the settings the supply setpoint temperature can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to the Override position A supply setpoint temperature continues to be calculated and displayed in Auto during the override In this way you can see the ...

Page 332: ...is purpose the slider must be dragged to one of the two Override positions Status Pump relay Outputs the status of the pump from the heat generator linked Pump operating status Outputs the operating status Off On provided by the pump On pumps with their own control this operating status can differ from the operating status of the heat generator Pump fault Outputs the fault status provided by the p...

Page 333: ...1 2CDC508198D0211 Rev A 333 This section displays the state of the heat generator linked Status Outputs the operating status provided by the heat generator linked Pump fault Outputs the fault status provided by the heat generator linked ...

Page 334: ...ture is calculated The settings on which the calculation is based can be changed The information displayed on this page may vary depending on which settings have been selected for the supply setpoint temperature calculation in the ASM settings This section shows the current status of the calculation These values cannot be changed by the user ...

Page 335: ...for heating for all rooms connected to the heating system This value is used by the Room involvement function Max room control value Outputs the highest heating control values valve positions for all rooms connected to the heating system The value is used by the Room involvement function to adjust the heating curve and therefore the supply setpoint temperature to the current needs This value is us...

Page 336: ...us so that the settings can be adapted to the local situation during the operating of the system without renewed ETS programming The settings on the web user interface always apply The parameters set in the ASM settings are overwritten and only become active again on the reinstallation of the ASM You will find the description of the ASM settings in the chapter 7 17 2 Settings ...

Page 337: ...nctions Custom heating curve chart If the supply setpoint temperature is calculated based on the weather and in the ASM settings the Custom option is selected for the Calculation formula parameter you can change the curve on the web user interface by specifying the points The points from the ASM settings parameterized are used as the initial values The settings on the web user interface always app...

Page 338: ...lication specific automation module ASM calculates the supply setpoint temperature and sends the value calculated to a cooling distribution circuit controller cooling circuit controller The module also permits the display and operation via the module s web user interface of the cooling distribution circuit controller linked ...

Page 339: ...i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 339 7 11 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM settings ...

Page 340: ...upply setpoint temperature source Options ASM input socket WebUI Input BACnet input object Calculated weather compensated This parameter determines how the supply setpoint temperature is determined for the cooling distribution circuit This setpoint is sent to the cooling distribution circuit controller via the group object ASM input socket The supply setpoint temperature received via the input soc...

Page 341: ...from the supply setpoint temperature and is limited by the Min supply temperature parameter Selection of WebUI Input or BACnet input object option Dependent parameter s Initial values Supply setpoint temperature Options 0 10 100 C This parameter defines the supply setpoint temperature that is output after downloading the module This value is output until a new value is entered on the web user inte...

Page 342: ...tton a window opens where you can add a custom supply temperature curve by changing the supply setpoint temperature The shape of the curve can be set as required by entering the points The limit specified via the Max supply temperature parameter is displayed on the chart as a red line This curve is used after downloading the module and can be modified via the web user interface for the module ...

Page 343: ...room valves in the cooling distribution circuit are available and connected to the ASM input socket There must therefore not be any conventional thermostats in the cooling distribution circuit This function is affected by the Enable cooling circuit control based on ASM input socket function If both functions are activated the Enable cooling circuit control based on ASM input socket has a higher pr...

Page 344: ...his object is forwarded to the cooling distribution circuit controller via a group object that is then displayed If the Switch off if no room demand function is also activated there is the following relationship ASM input socket Control On Off Heating cooling distribution circuit controller control Result of the Switch off if no room demand function Result and output in the Control On Off group ob...

Page 345: ...are adjusted to suit the setting Override by WebUI Options No checkbox cleared Yes checkbox selected If this function is activated the pump can be overridden via the web user interface For this purpose additional group objects are displayed that must be connected to the cooling distribution circuit controller Pump display operating status Options No checkbox cleared Yes checkbox selected If the pu...

Page 346: ...put on the web user interface in a BACnet object and on the ASM socket The ASM only displays this state there are no switching actions based on the fault status Display pump repair switch status Options No checkbox cleared Yes checkbox selected If the pump has a repair switch and the contact position is output this status can be received by a group object via this function and output on the web us...

Page 347: ...ve option Dependent parameter s Status Valve purge Options No checkbox cleared Yes checkbox selected If this function is activated the status of the valve purge can be received by a group object and output on the web user interface in a BACnet object and on the ASM socket Valve override disable enable Options No checkbox cleared Yes checkbox selected If this function is activated the valve can be ...

Page 348: ...l On Off 1 001 Output Valve override disable enable 1 003 Output Valve override control value 5 001 Output Status Valve purge 1 011 Output Pump A operating status Off On 1 011 Output Pump A relay status 1 001 Output Pump A fault 1 005 Output Pump A repair switch status 1 011 Output Pump A override disable enable 1 003 Output Pump A override value 1 001 Output Pump B operating status Off On 1 011 O...

Page 349: ...ation of the supply setpoint temperature by another module This value is output in the corresponding group objects to the cooling distribution circuit controller linked Note The value can be affected by the Min supply temperature and Supply setpoint temperature offset parameters in the module Signal value 273 670760 C Outside temperature DPT 9 001 This module has this input socket if the Yes optio...

Page 350: ...Signal value 273 670760 C Return temperature DPT 9 001 Outputs the current return temperature that is received via the related group object Signal value 273 670760 C Control On Off DPT 1 001 The module has this output socket in the following conditions If the Yes option is selected for the Supply temperature control parameter and the Yes option is selected for the Enable cooling circuit control ba...

Page 351: ...Signal value 0 100 Status Valve purge DPT 1 011 The module has this output socket if the 3 way valve mixing valve option or the 2 way valve option is selected for the Valve type parameter and the Yes option is selected for the Status Valve purge parameter Outputs the status as to whether the cooling distribution circuit controller is actually undertaking a valve purge This value is received from t...

Page 352: ...atus parameter Outputs the contact position provided by the pump repair switch Signal value 0 Inactive 1 Active Pump A override disable enable DPT 1 003 The module has this output socket if the Yes option is selected for the Override by WebUI parameter Outputs whether the pump for the cooling distribution circuit is overridden Signal value 0 Disabled 1 Enabled Pump A override value DPT 1 001 The m...

Page 353: ...output socket if the Yes option is selected for the Double pump parameter Outputs the status of the second pump from the cooling distribution circuit controller Signal value 0 Off 1 On Pump B fault DPT 1 005 The module has this output socket if the Yes option is selected for the Double pump parameter and the Yes option is selected for the Pump display pump fault status parameter Outputs the fault ...

Page 354: ...s option is selected for the Supply temperature control parameter Outputs the current supply setpoint temperature as is sent by the module to the cooling distribution circuit controller via the related group object The supply setpoint temperature output here is depending on the setting either calculated by this module based on the outside temperature or specified via an ASM input socket or BACnet ...

Page 355: ...ion circuit 1 011 1 bit x x x Input Pump A repair switch status Cooling distribution circuit 1 011 1 bit x x x Input Pump A fault Cooling distribution circuit 1 011 1 bit x x x Input Pump A operating status Off On Cooling distribution circuit 1 011 1 bit x x x In Output Pump A override disable enable Cooling distribution circuit 1 003 1 bit x x x x In Output Pump A override value Cooling distribut...

Page 356: ...T Input for supply temperature measured in the cooling distribution circuit Telegram value 273 670760 C Input Return temperature Cooling distribution circuit 2 bytes DPT 9 001 C W T Input for return temperature measured in the cooling distribution circuit Telegram value 273 670760 C Output Supply setpoint temperature Cooling distribution circuit 2 bytes DPT 9 001 C R T Outputs the supply setpoint ...

Page 357: ...Yes option is selected for the Valve override disable enable parameter This object specifies the control value valve position used to override the valve for the cooling distribution circuit if the valve override is active Telegram value 0 100 Input Status Valve purge Cooling distribution circuit 1 bit DPT 1 011 C W T The module has this group object if the 3 way valve mixing valve option or the 2 ...

Page 358: ... On provided by the pump On pumps with their own control this operating status can differ from the operating status of the cooling distribution circuit controller Telegram value 0 Inactive 1 Active In Output Pump A override disable enable Cooling distribution circuit 1 bit DPT 1 003 C R W T The module has this group object if the Yes option is selected for the Override by WebUI parameter This obje...

Page 359: ...ect activates deactivates the second pump override for the cooling distribution circuit controller Telegram value 0 Disabled 1 Enabled In Output Pump B override value Cooling distribution circuit 1 bit DPT 1 001 C R W T The module has this group object if the Yes option is selected for the Double pump parameter and the Yes option is selected for the Override by WebUI parameter This object specifie...

Page 360: ...nput Pump B relay status Cooling distribution circuit 1 bit DPT 1 001 C W T The module has this group object if the Yes option is selected for the Double pump parameter Input for the status of the second pump from the cooling distribution circuit controller Telegram value 0 Off 1 On Output Control On Off Cooling distribution circuit 1 bit DPT 1 001 C R T The module has this group object in the fol...

Page 361: ...8 1 0 Output Cooling distribution circuit Pump A override disable enable Binary value Output Cooling distribution circuit Pump A override value Binary value Output Cooling distribution circuit Pump A operating status Off On Binary value Output Cooling distribution circuit Pump A relay status Binary value Output Cooling distribution circuit Pump A fault Binary value Output Cooling distribution circ...

Page 362: ...distribution circuit Return temperature Analog value C 62 1 0 Outputs the current return temperature that is received via the related group object Signal value 273 670760 C Cooling distribution circuit Supply temperature Analog value C 62 1 0 Outputs the current supply temperature that is received via the related group object Signal value 273 670760 C Cooling distribution circuit Supply setpoint t...

Page 363: ...stribution circuit Supply setpoint temperature External specification Analog value C 62 1 0 This module has this BACnet input object if the Yes option is selected for the Supply temperature control parameter and the ASM input socket option is selected for the Supply setpoint temperature source parameter Outputs the supply setpoint temperature specified via the ASM input socket This status does not...

Page 364: ...Analog value 98 1 0 The module has this BACnet output object if the Yes option is selected for the Switch off if no room demand parameter Outputs the highest room setpoint temperature that is present on the ASM input socket and that is used by the Economy mode and Switch off if no room demand functions Signal value 0 100 Cooling distribution circuit Pump A override disable enable Binary value The ...

Page 365: ...ng distribution circuit Pump A fault Binary value The module has this BACnet output object if the Yes option is selected for the Pump display pump fault status parameter Outputs the fault status provided by the pump Signal value 0 Inactive 1 Active Cooling distribution circuit Pump A repair switch status Binary value The module has this BACnet output object if the Yes option is selected for the Di...

Page 366: ...ption is selected for the Pump display operating status parameter Outputs the operating status Off On provided by the second pump On pumps with their own control this operating status can differ from the operating status of the cooling distribution circuit controller Signal value 0 Inactive 1 Active Cooling distribution circuit Pump B relay status Binary value The module has this BACnet output obj...

Page 367: ... or the 2 way valve option is selected for the Valve type parameter and the Yes option is selected for the Valve override disable enable parameter Outputs whether the override of the cooling distribution circuit s valve is active or inactive Signal value 0 Disabled 1 Enabled Cooling distribution circuit Valve override control value Analog value 98 1 0 The module has this BACnet output object if th...

Page 368: ...s section shows the current operating status of the cooling distribution circuit controller linked via KNX If activated in the settings the control by the cooling distribution circuit controller can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to one of the two Override positions The current state of the cooling distribution cir...

Page 369: ...odule This temperature is sent via KNX to the cooling distribution circuit controller linked If activated in the settings the supply setpoint temperature can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to the Override position A supply setpoint temperature continues to be calculated and displayed in Auto during the override In ...

Page 370: ... controller can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to one of the two Override positions Status Pump relay Outputs the status of the pump from the cooling distribution circuit controller linked Pump operating status Outputs the operating status Off On provided by the pump On pumps with their own control this operating s...

Page 371: ... It is also indicated whether a valve purge is in progress If activated in the settings the valve position can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to the Override position The status sent by the cooling distribution circuit controller continues to be displayed in Auto during the override ...

Page 372: ...ttings can be changed in this section via the web user interface This is advantageous so that the settings can be adapted to the local situation during the operating of the system without renewed ETS programming The settings on the web user interface always apply The parameters set in the ASM settings are overwritten and only become active again on the reinstallation of the ASM The supply setpoint...

Page 373: ...ted based on the weather you can change the curve on the web user interface by specifying the points The points from the ASM settings parameterized are used as the initial values The settings on the web user interface always apply The parameters set in the ASM settings are overwritten and only become active again on the reinstallation of the ASM ...

Page 374: ...ler ASM 7 12 1 General This application specific automation module ASM calculates the supply setpoint temperature and sends the value calculated to a chiller linked via KNX The module also allows the chiller to be displayed and operated via the module s web user interface ...

Page 375: ...i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 375 7 12 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter 7 3 Global ASM settings ...

Page 376: ...unction Result and output in the Chiller On Off group object Off Switched off Off On Switched off On Off Switched on Off On Switched on On Show operating status Options No checkbox cleared Yes checkbox selected If the chiller outputs its operating status Off On this status can be received by a group object via this function and output on the web user interface in a BACnet object and on the ASM soc...

Page 377: ...int temperature source Options ASM input socket WebUI Input BACnet input object Calculated weather compensated This parameter determines how the supply setpoint temperature is determined for the chiller This setpoint is sent to the chiller via the group object ASM input socket The supply setpoint temperature received via the input socket on the ASM is used This is an ASM multiple socket on which t...

Page 378: ...from the supply setpoint temperature and is limited by the Min supply temperature parameter Selection of WebUI Input or BACnet input object option Dependent parameter s Initial values Supply setpoint temperature Options 0 10 100 C This parameter defines the supply setpoint temperature that is output after downloading the module This value is output until a new value is entered on the web user inte...

Page 379: ...tton a window opens where you can add a custom supply temperature curve by changing the supply setpoint temperature The shape of the curve can be set as required by entering the points The limit specified via the Max supply temperature parameter is displayed on the chart as a red line This curve is used after downloading the module and can be modified via the web user interface for the module ...

Page 380: ...his function that all control values from the room valves in the cooling system are available and connected to the ASM input socket There must therefore not be any conventional thermostats in the cooling system This function is affected by the Enable chiller based on ASM input socket function If both functions are activated the Enable chiller based on ASM input socket has a higher priority Selecti...

Page 381: ...uit the setting Override by WebUI Options No checkbox cleared Yes checkbox selected If this function is activated the pump can be overridden via the web user interface For this purpose additional group objects are displayed that must be connected to the chiller Pump display operating status Options No checkbox cleared Yes checkbox selected If the pump outputs its operating status Off On this statu...

Page 382: ...put on the web user interface in a BACnet object and on the ASM socket The ASM only displays this state there are no switching actions based on the fault status Display pump repair switch status Options No checkbox cleared Yes checkbox selected If the pump has a repair switch and the contact position is output this status can be received by a group object via this function and output on the web us...

Page 383: ...om control values 5 001 Output Supply temperature 9 001 Output Return temperature 9 001 Output Chiller On Off 1 001 Output Pump operating status Off On 1 011 Output Pump relay status 1 001 Output Pump fault 1 005 Output Pump repair switch status 1 011 Output Pump override disable enable 1 003 Output Pump override value 1 001 Output Supply setpoint temperature 9 001 Output Supply setpoint temperatu...

Page 384: ...etpoint temperature by another module This value is output in the corresponding group objects to the chiller linked Note The value can be affected by the Min supply temperature and Supply setpoint temperature offset parameters in the module Signal value 273 670760 C Outside temperature DPT 9 001 This module has this input socket if the Yes option is selected for the Supply temperature control para...

Page 385: ...based on ASM input socket parameter If the Yes option is selected for the Switch off if no room demand parameter Outputs the on off status of the chiller that is sent to the chiller via the related group object The state is dependent on the Enable chiller based on ASM input socket and Switch off if no room demand parameters Signal value 0 Off 1 On Pump operating status Off On DPT 1 011 The module ...

Page 386: ...pump repair switch status parameter Outputs the contact position provided by the pump repair switch Signal value 0 Inactive 1 Active Pump override disable enable DPT 1 003 The module has this output socket if the Yes option is selected for the Override by WebUI parameter Outputs whether the pump for the chiller is overridden Signal value 0 Disabled 1 Enabled Pump override value DPT 1 001 The modul...

Page 387: ...utput socket if the Yes option is selected for the Supply temperature control parameter and the BACnet input object option is selected for the Supply setpoint temperature source parameter Outputs the supply setpoint temperature specified via the BACnet object This status does not take into account any possible override of the supply setpoint temperature via the web user interface Signal value 273 ...

Page 388: ...iller 9 001 2 bytes x x x Input Pump relay status Chiller 1 001 1 bit x x x Input Pump repair switch status Chiller 1 011 1 bit x x x Input Pump fault Chiller 1 011 1 bit x x x Input Pump operating status Off On Chiller 1 011 1 bit x x x In Output Pump override disable enable Chiller 1 003 1 bit x x x x In Output Pump override value Chiller 1 001 1 bit x x x x Output Chiller On Off Chiller 1 001 1...

Page 389: ...emperature Chiller 2 bytes DPT 9 001 C R T Outputs the supply setpoint temperature calculated by the module as the value specified to the chiller Telegram value 273 670760 C Input Pump relay status Chiller 1 bit DPT 1 001 C W T Input for the status of the pump from the chiller Telegram value 0 Off 1 On Input Pump repair switch status Chiller 1 bit DPT 1 011 C W T The module has this group object i...

Page 390: ...arameter Input for the operating status Off On provided by the pump On pumps with their own control this operating status can differ from the operating status of the chiller Telegram value 0 Inactive 1 Active In Output Pump override disable enable Chiller 1 bit DPT 1 003 C R W T The module has this group object if the Yes option is selected for the Override by WebUI parameter This object activates...

Page 391: ...f via this group object based on the calculations in the module Telegram value 0 Off 1 On Input Chiller operating status Chiller 1 bit DPT 1 011 C W T The module has this group object if the Yes option is selected for the Show operating status parameter Input for the operating status Off On provided by the chiller Due to the control integrated into the chiller this status may differ from the opera...

Page 392: ...lt status Binary value Output Chiller Room control values Analog value 98 1 0 Output Chiller Pump override disable enable Binary value Output Chiller Pump override value Binary value Output Chiller Pump operating status Off On Binary value Output Chiller Pump relay status Binary value Output Chiller Pump fault Binary value Output Chiller Pump repair switch status Binary value BACnet input objects ...

Page 393: ...e temperature or specified via an ASM input socket or BACnet and also takes into account any possible override of the supply setpoint temperature via the web user interface Signal value 273 670760 C Chiller Outside temperature Analog value C 62 1 0 This module has this BACnet output object if the Yes option is selected for the Supply temperature control parameter and the Calculated weather compens...

Page 394: ...ature control parameter and the Yes option is selected for the Enable chiller based on ASM input socket parameter If the Yes option is selected for the Switch off if no room demand parameter Outputs the on off status of the chiller that is sent to the chiller via the related group object The state is dependent on the Enable chiller based on ASM input socket and Switch off if no room demand functio...

Page 395: ...ACnet output object if the Yes option is selected for the Show fault status parameter Outputs the fault status provided by the chiller Signal value 0 Off 1 On Chiller Room control values Analog value 98 1 0 The module has this BACnet output object if the Yes option is selected for the Switch off if no room demand parameter Outputs the highest room setpoint temperature that is present on the ASM in...

Page 396: ...ating status Off On provided by the pump On pumps with their own control this operating status can differ from the operating status of the chiller Signal value 0 Inactive 1 Active Chiller Pump relay status Binary value Outputs the status of the chiller s pump Signal value 0 Off 1 On Chiller Pump fault Binary value The module has this BACnet output object if the Yes option is selected for the Pump ...

Page 397: ... the individual sections Chiller page This section shows the current operating status of the chiller linked via KNX If activated in the settings the control by the chiller can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to one of the two Override positions The current state of the chiller continues to be displayed in Auto durin...

Page 398: ...odule This temperature is sent via KNX to the chiller linked If activated in the settings the supply setpoint temperature can be overridden by the admin and expert users via the web user interface For this purpose the slider must be dragged to the Override position A supply setpoint temperature continues to be calculated and displayed in Auto during the override In this way you can see the value t...

Page 399: ...is purpose the slider must be dragged to one of the two Override positions Status Pump relay Outputs the status of the pump from the chiller linked Pump operating status Outputs the operating status Off On provided by the pump On pumps with their own control this operating status can differ from the operating status of the chiller Pump fault Outputs the fault status provided by the pump Repair swi...

Page 400: ... 400 2CDC508198D0211 Rev A AC S 1 x 1 This section displays the state of the chiller linked Status Outputs the operating status provided by the chiller linked Pump fault Outputs the fault status provided by the chiller linked ...

Page 401: ...ttings can be changed in this section via the web user interface This is advantageous so that the settings can be adapted to the local situation during the operating of the system without renewed ETS programming The settings on the web user interface always apply The parameters set in the ASM settings are overwritten and only become active again on the reinstallation of the ASM The supply setpoint...

Page 402: ...ted based on the weather you can change the curve on the web user interface by specifying the points The points from the ASM settings parameterized are used as the initial values The settings on the web user interface always apply The parameters set in the ASM settings are overwritten and only become active again on the reinstallation of the ASM ...

Page 403: ...ed for a system with heating and cooling functions Depending on the setting made the operating type is calculated based on the outside temperature or on the supply temperature The module outputs the current operating type on the KNX bus on the ASM output socket and on BACnet 7 13 2 Settings General You will find descriptions of the global settings Name Description Reinstall BACnet WebUI in chapter...

Page 404: ... set here Heating if less than Options 10 17 100 C The heating operating type is activated as soon as the outside temperature at the ASM drops below the value set here Selection of Supply temperature option Dependent parameter s Cooling if less than Options 10 15 100 C The cooling operating type is activated as soon as the supply temperature at the ASM drops below the value set here This means tha...

Page 405: ...if the outside temperature supply temperature at the ASM exceeds or is below the changeover temperatures set above If the outside temperature supply temperature at the ASM is however between these two changeover temperatures it is not possible to determine the operating type unambiguously For this reason the operating type last active is used on a device start After downloading the ASM the operati...

Page 406: ...ature or the supply temperature must be connected to this input socket depending on the setting selected above The changeover between heating and cooling is undertaken based on the temperature present here Signal value 273 670760 C Output sockets Object name Data type Operating type DPT 1 100 Outputs the active operating type Signal value 0 Cooling 1 Heating Heating DPT 1 001 Outputs the state of ...

Page 407: ...r 1 bit DPT 1 100 C R T Outputs the active operating type The value is sent on every change and then repeated every 30 minutes The cycle time cannot be changed Telegram value 0 Cooling 1 Heating Output Heating Heating cooling changeover 1 bit DPT 1 001 C R T Outputs the state of the heating operating type The value is sent on every change and then repeated every 30 minutes The cycle time cannot be...

Page 408: ... AC S 1 x 1 7 13 5 BACnet objects BACnet input objects None BACnet output objects Object name Object type Unit COV send condition Heating cooling changeover Operating type Binary value Outputs the active operating type Signal value 0 Cooling 1 Heating ...

Page 409: ...ers can override the current operating type For the other users this field is dimmed and can therefore not be changed The automatic calculation of the operating type continues to run during the override and the automatically calculated operating type is also displayed on the web user interface in Auto The operating type is only output in the group objects on the ASM output sockets and in the BACne...

Page 410: ...nterface Switching commands can be set to the minute for each weekday and exceptions e g for holidays can be defined on a weekly monthly and yearly basis The application controller outputs the switching command on the KNX bus on the ASM output socket and on BACnet Note It is essential the clock in the application controller is set to operate this module 7 14 2 Settings General You will find descri...

Page 411: ...urrent value based on the scheduler is output for the linking to other modules Signal value 1 Comfort 2 Standby 3 Economy 4 Building Protection 7 14 4 Group objects Object function Name can be changed separately Data type Flags Output State Operating mode Scheduler WebUI 1 byte DPT 20 102 C R T The current value based on the scheduler is output Telegram value 1 Comfort 2 Standby 3 Economy 4 Buildi...

Page 412: ...BACnet objects BACnet input objects None BACnet output objects Object name Object type Unit COV send condition Operating mode Scheduler WebUI State Positive integer value 95 No Units 1 0 The current operating mode based on the scheduler is output Signal value 0 Off 1 On ...

Page 413: ... Exceptions Set the rules for exceptions for instance for holidays on the Exceptions page These exceptions override the switching times specified on the Week page Calendar The resulting switching times are displayed on the Calendar page You can select each date and view the switching times set for this day consisting of the weekly switching times and the exceptions defined It is not possible to ch...

Page 414: ...ABB i bus KNX Parameters 414 2CDC508198D0211 Rev A AC S 1 x 1 ...

Page 415: ...g command by dragging the circle horizontally or by clicking the buttons beside the circle An existing switching time can be converted to a different switching command E g a COMFORT switching command can be changed into a STANDBY switching command by first clicking STANDBY on the action bar and then clicking the COMFORT switching time to be changed It is not possible to change existing switching c...

Page 416: ...of the week page An exception can cover one or more days The exception replaces all switching times on a day Click the Add exception button to add a new exception you can assign a specific name for the exception in the Name field If a name is not specified a name is generated automatically on saving Set the switching times as described for the Week page ...

Page 417: ...ABB i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 417 In the section underneath set the days to which this exception is to apply ...

Page 418: ...y The selection is marked in blue and is displayed in the two date fields as the start and end date for the exception Alternatively you can enter the start and end date directly in the date fields Programming over several months is possible Yearly tab Here you can set an exception for a day or for a contiguous sequence of days that is applied every year Program the exception using the procedure de...

Page 419: ... days of the week if you clear the checkbox in the weekday bar individual days can be excluded from the exception The blue marking on the calendar is changed to suit Click the Create exception button to save the exception the programming is then active Click the Cancel button to cancel the addition of the exception The exception switching times can overlap In this situation the exception switching...

Page 420: ... the complete week containing the selected day is also displayed in the overview rows underneath General Any change to the timer on the web user interface is saved and becomes active immediately Several users can access the scheduler on the web user interface and make changes at the same time These changes are copied to the other users in real time Only exception switching times cannot be edited a...

Page 421: ...et to the minute for each weekday and exceptions e g for holidays can be defined on a weekly monthly and yearly basis The application controller outputs the switching command on the KNX bus on the ASM output socket and on BACnet Note It is essential the clock in the application controller is set to operate this module 7 15 2 Settings General You will find descriptions of the global settings Name D...

Page 422: ...ts Object name Data type State DPT 1 001 The current value based on the scheduler is output for the linking to other modules Signal value 0 Off 1 On 7 15 4 Group objects Object function Name can be changed separately Data type Flags Output State ON OFF Scheduler WebUI 1 bit DPT 1 001 C R T The current value based on the scheduler is output Telegram value 0 Off 1 On ...

Page 423: ...0211 Rev A 423 7 15 5 BACnet objects BACnet input objects None BACnet output objects Object name Object type Unit COV send condition ON OFF Scheduler WebUI State Binary value The current value based on the scheduler is output Signal value 0 Off 1 On ...

Page 424: ... Exceptions Set the rules for exceptions for instance for holidays on the Exceptions page These exceptions override the switching times specified on the Week page Calendar The resulting switching times are displayed on the Calendar page You can select each date and view the switching times set for this day consisting of the weekly switching times and the exceptions defined It is not possible to ch...

Page 425: ...ABB i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 425 ...

Page 426: ...y dragging the circle horizontally or by clicking the buttons beside the circle An existing switching time can be converted to a different switching command E g an ON switching command can be changed into an OFF switching command by first clicking OFF on the action bar and then clicking the ON switching time to be changed It is not possible to change existing switching commands by dragging drag dr...

Page 427: ...of the week page An exception can cover one or more days The exception replaces all switching times on a day Click the Add exception button to add a new exception you can assign a specific name for the exception in the Name field If a name is not specified a name is generated automatically on saving Set the switching times as described for the Week page ...

Page 428: ...ABB i bus KNX Parameters 428 2CDC508198D0211 Rev A AC S 1 x 1 In the section underneath set the days to which this exception is to apply ...

Page 429: ...y The selection is marked in blue and is displayed in the two date fields as the start and end date for the exception Alternatively you can enter the start and end date directly in the date fields Programming over several months is possible Yearly tab Here you can set an exception for a day or for a contiguous sequence of days that is applied every year Program the exception using the procedure de...

Page 430: ... days of the week if you clear the checkbox in the weekday bar individual days can be excluded from the exception The blue marking on the calendar is changed to suit Click the Create exception button to save the exception the programming is then active Click the Cancel button to cancel the addition of the exception The exception switching times can overlap In this situation the exception switching...

Page 431: ... the complete week containing the selected day is also displayed in the overview rows underneath General Any change to the timer on the web user interface is saved and becomes active immediately Several users can access the scheduler on the web user interface and make changes at the same time These changes are copied to the other users in real time Only exception switching times cannot be edited a...

Page 432: ...an be set to the minute for each weekday and exceptions e g for holidays can be defined on a weekly monthly and yearly basis The application controller outputs the switching command on the KNX bus on the ASM output socket and on BACnet Note It is essential the clock in the application controller is set to operate this module 7 16 2 Settings General You will find descriptions of the global settings...

Page 433: ...ect name Data type State DPT 9 001 The current value based on the scheduler is output for the linking to other modules Signal value 273 670760 C 7 16 4 Group objects Object function Name can be changed separately Data type Flags Output State Temperature Scheduler WebUI 2 bytes DPT 9 001 C R T The current value based on the scheduler is output Telegram value 273 670760 C ...

Page 434: ...x 1 7 16 5 BACnet objects BACnet input objects None BACnet output objects Object name Object type Unit COV send condition Temperature Scheduler WebUI State Analog value C 62 1 0 The current temperature based on the scheduler is output Signal value 273 670760 C ...

Page 435: ... Exceptions Set the rules for exceptions for instance for holidays on the Exceptions page These exceptions override the switching times specified on the Week page Calendar The resulting switching times are displayed on the Calendar page You can select each date and view the switching times set for this day consisting of the weekly switching times and the exceptions defined It is not possible to ch...

Page 436: ...ABB i bus KNX Parameters 436 2CDC508198D0211 Rev A AC S 1 x 1 ...

Page 437: ...ching command on the next day then becomes active You can adjust the start time for a switching command by dragging the circle horizontally or by clicking the buttons beside the circle You adjust the temperature for a switching command by dragging the circle on the left or by clicking the buttons beside the circle You can copy the switching times on one day to another day by dragging the Copy icon...

Page 438: ...of the week page An exception can cover one or more days The exception replaces all switching times on a day Click the Add exception button to add a new exception you can assign a specific name for the exception in the Name field If a name is not specified a name is generated automatically on saving Set the switching times as described for the Week page ...

Page 439: ...ABB i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 439 In the section underneath set the days to which this exception is to apply ...

Page 440: ...y The selection is marked in blue and is displayed in the two date fields as the start and end date for the exception Alternatively you can enter the start and end date directly in the date fields Programming over several months is possible Yearly tab Here you can set an exception for a day or for a contiguous sequence of days that is applied every year Program the exception using the procedure de...

Page 441: ... days of the week if you clear the checkbox in the weekday bar individual days can be excluded from the exception The blue marking on the calendar is changed to suit Click the Create exception button to save the exception the programming is then active Click the Cancel button to cancel the addition of the exception The exception switching times can overlap In this situation the exception switching...

Page 442: ... the complete week containing the selected day is also displayed in the overview rows underneath General Any change to the timer on the web user interface is saved and becomes active immediately Several users can access the scheduler on the web user interface and make changes at the same time These changes are copied to the other users in real time Only exception switching times cannot be edited a...

Page 443: ...ication controller The switching times can be viewed via the web user interface The application controller outputs the switching command on the KNX bus and on the ASM output socket The application controller ensures that the switching commands are executed even if there is a malfunction in the BACnet system Note It is essential the clock in the application controller is set to operate this module ...

Page 444: ...after downloading the module to the application controller Properties panel BACnet Calendar Activated Options No checkbox cleared Yes checkbox selected In the BACnet parameter window for this module you can activate a BACnet calendar object on the BACnet interface This BACnet calendar object can be used to define an additional exception calendar and to link this to any BACnet scheduler in the BACn...

Page 445: ...urrent value based on the scheduler is output for the linking to other modules Signal value 1 Comfort 2 Standby 3 Economy 4 Building Protection 7 17 4 Group objects Object function Name can be changed separately Data type Flags Output State Operating mode Scheduler BACnet 1 byte DPT 20 102 C R T The current value based on the scheduler is output Telegram value 1 Comfort 2 Standby 3 Economy 4 Build...

Page 446: ...e Use this BACnet object of type Schedule to parametrize the switching times with the related operating types via BACnet Signal value 1 Comfort 2 Standby 3 Economy 4 Building Protection Operating mode Scheduler BACnet Calendar Calendar The module has this BACnet input object if the Yes option is selected for the Activated parameter in Calendar section of the BACnet parameter window This BACnet cal...

Page 447: ...ern for the complete week containing the selected day is also displayed in the overview rows underneath The view is intended to provide an overview and to be used for checking It is not possible to change the switching times via the web user interface The resulting switching times are displayed on the web user interface These represent the combination of the BACnet weekly scheduler and the BACnet ...

Page 448: ...es can be viewed via the web user interface The application controller outputs the switching command on the KNX bus and on the ASM output socket The application controller ensures that the switching commands are executed even if there is a malfunction in the BACnet system Note It is essential the clock in the application controller is set to operate this module 7 18 2 Settings General You will fin...

Page 449: ...the module to the application controller Properties panel BACnet Calendar Activated Options No checkbox cleared Yes checkbox selected In the BACnet parameter window for this module you can activate a BACnet calendar object on the BACnet interface This BACnet calendar object can be used to define an additional exception calendar and to link this to any BACnet scheduler in the BACnet system You will...

Page 450: ...s Object name Data type State DPT 1 001 The current value based on the scheduler is output for the linking to other modules Signal value 0 Off 1 On 7 18 4 Group objects Object function Name can be changed separately Data type Flags Output State ON OFF Scheduler BACnet 1 bit DPT 1 001 C R T The current value based on the scheduler is output Telegram value 0 Off 1 On ...

Page 451: ... Scheduler BACnet State Schedule Use this BACnet object of type Schedule to parameterize the switching times via BACnet Signal value 0 Off 1 On ON OFF Scheduler BACnet Calendar Calendar The module has this BACnet input object if the Yes option is selected for the Activated parameter in Calendar section of the BACnet parameter window This BACnet calendar object can be used to define an additional e...

Page 452: ...ern for the complete week containing the selected day is also displayed in the overview rows underneath The view is intended to provide an overview and to be used for checking It is not possible to change the switching times via the web user interface The resulting switching times are displayed on the web user interface These represent the combination of the BACnet weekly scheduler and the BACnet ...

Page 453: ...ing times can be viewed via the web user interface The application controller outputs the switching command on the KNX bus and on the ASM output socket The application controller ensures that the switching commands are executed even if there is a malfunction in the BACnet system Note It is essential the clock in the application controller is set to operate this module 7 19 2 Settings General You w...

Page 454: ...ing the module to the application controller Properties panel BACnet Calendar Activated Options No checkbox cleared Yes checkbox selected In the BACnet parameter window for this module you can activate a BACnet calendar object on the BACnet interface This BACnet calendar object can be used to define an additional exception calendar and to link this to any BACnet scheduler in the BACnet system You ...

Page 455: ...ect name Data type State DPT 9 001 The current value based on the scheduler is output for the linking to other modules Signal value 273 670760 C 7 19 4 Group objects Object function Name can be changed separately Data type Flags Output State Temperature Scheduler BACnet 2 bytes DPT 9 001 C R T The current value based on the scheduler is output Telegram value 273 670760 C ...

Page 456: ...ture Scheduler BACnet State Schedule Multistate Use this BACnet object of type Schedule to parameterize the switching times via BACnet Signal value 273 670760 C Temperature Scheduler BACnet Calendar Calendar The module has this BACnet input object if the Yes option is selected for the Activated parameter in Calendar section of the BACnet parameter window This BACnet calendar object can be used to ...

Page 457: ...ern for the complete week containing the selected day is also displayed in the overview rows underneath The view is intended to provide an overview and to be used for checking It is not possible to change the switching times via the web user interface The resulting switching times are displayed on the web user interface These represent the combination of the BACnet weekly scheduler and the BACnet ...

Page 458: ...nd are then forwarded by these for recording The Trend ASM itself does not have any group objects or BACnet objects The data point type is freely selectable for each input value The recording duration and the recording frequency are set to suit the required application The Trend ASM has a ring memory that automatically deletes the oldest entries If a recording duration of 1 year is selected for ex...

Page 459: ...e application controller receives summer winter time changeover information via NTP KNX or BACnet then On a clock change to summer time the time 2 am is not displayed On a clock change to winter time the time 2 am is recorded and displayed twice On a change independent of summer winter time to the time via NTP KNX or BACnet If the time is moved forward there will be period without trends If the ti...

Page 460: ...mber of trends Options 1 2 3 4 5 This parameter specifies how many independent values are to be recorded by the module An ASM input socket is activated for each value and the following parameters displayed Note The settings for Trend 1 5 are explained in the following based on Trend 1 The settings are identical for all trends Trend1 Name Name of the trend line that is displayed on the web user int...

Page 461: ...ata point types can be selected 1 xxx 1 bit o 1 o 1 001 switch o 1 002 boolean o 1 003 enable o 1 004 rise o 1 005 alarm o 1 006 binary value o 1 007 step o 1 008 up down o 1 009 open close o 1 010 start stop o 1 011 status o 1 012 inversion o 1 013 dimming send type o 1 014 input type 5 xxx 8 bit unsigned o 5 o 5 001 percentage 0 100 o 5 003 angle degrees o 5 004 percentage 0 255 o 5 005 ratio 0 ...

Page 462: ...ference h o 8 010 percent difference o 8 011 angle of rotation 9 xxx 2 byte floating point value o 9 o 9 001 temperature C o 9 002 temperature difference K o 9 003 kelvin hour K h o 9 004 lux Lux o 9 005 speed m s o 9 006 pressure Pal o 9 007 humidity o 9 008 parts million ppm o 9 010 time s o 9 011 time ms o 9 020 voltage mV o 9 021 current mA o 9 022 power density W m2 o 9 023 kelvin percent K o...

Page 463: ... 4 byte floating point value o 14 o 14 000 acceleration m s2 o 14 001 angular acceleration rad s2 o 14 002 molar energy J mol o 14 003 radioactivity 1 s o 14 004 amount of substance mol o 14 005 amplitude o 14 006 angle radian o 14 007 angle degree o 14 008 angular momentum Js o 14 009 angular frequency rad s o 14 010 area m2 o 14 011 capacitance F o 14 012 flux density C m2 o 14 013 charge densit...

Page 464: ...4 033 frequency Hz o 14 034 angular frequency rad s o 14 035 heat capacity J K o 14 036 heat flux W o 14 037 quantity of heat J o 14 038 resistance Ω o 14 039 length m o 14 040 quantity of light J o 14 041 brightness cd m2 o 14 042 luminous flux lm o 14 043 luminosity cd o 14 044 magnetic field strength A m o 14 045 magnetic flux Wb o 14 046 magnetic flux density T o 14 047 magnetic moment Am2 o 1...

Page 465: ... volume W m2 o 14 065 velocity m s o 14 066 load Pa o 14 067 surface tension N m o 14 068 temperature C o 14 069 absolute temperature C o 14 070 temperature difference K o 14 071 heat capacity J K o 14 072 heat conductivity W mK o 14 073 thermoelectrical energy V K o 14 074 time s o 14 075 torque Nm o 14 076 volume m3 o 14 077 flow rate m3 s o 14 078 weight N o 14 079 work J You will find further ...

Page 466: ...e has this input socket if the 2 option or greater is selected for the Number of trends parameter Input for recorded value 2 Signal value Configuration dependent Trend3 Configuration dependent The module has this input socket if the 3 option or greater is selected for the Number of trends parameter Input for recorded value 3 Signal value Configuration dependent Trend4 Configuration dependent The m...

Page 467: ...ABB i bus KNX Parameters AC S 1 x 1 2CDC508198D0211 Rev A 467 Output sockets None 7 20 4 Group objects No objects available 7 20 5 BACnet objects No objects available ...

Page 468: ...B i bus KNX Parameters 468 2CDC508198D0211 Rev A AC S 1 x 1 7 20 6 Web user interface Open the detailed view of the ASM by clicking the ASM s tile The user interface has the following layout and functions ...

Page 469: ...duration selected and the recording frequency You can hide and show values by clicking the related marker in the Legend section A dedicated diagram area is displayed for each data point type used If several objects with the same data point type are recorded these are displayed in the same chart area with different colors Calendar function Used to enter the required period from to Slider Used to li...

Page 470: ...e is at the value of the previous point measured These lines are theoretical and do not represent the values present at this time linear interpolation Export You can print the trends using this function or export them to the file formats PNG JPG PDF XLSX CSV JSON Only the period actually displayed in the chart area is exported Newly recorded values are not added to the chart while the web user int...

Page 471: ... ETS Note There is only an overview of the general group objects at this point The tables of ASM specific group objects are given in chapter 7 in the related ASM description No Object function Name Data point type DPT Length Flags C R W T U I 2001 Request time Device clock 1 017 1 bit x x 2002 Date Device clock 11 001 3 bytes x x x x 2003 Time Device clock 10 001 3 bytes x x x x 2004 Date Time Dev...

Page 472: ...t 2003 Time Device clock 3 bytes DPT 10 001 C R W T This group object receives the time from KNX if KNX was selected as the clock synchronization source in the DCA device settings In all other cases the device time can be sent on the bus via this group object Only time information is evaluated Day of the week information is not taken into account 2004 Date Time Device clock 8 bytes DPT 19 001 C R ...

Page 473: ...ABB i bus KNX Operation AC S 1 x 1 2CDC508198D0211 Rev A 473 9 Operation 9 1 Manual operation You can restart the device by pressing the Reset button See chapter 4 6 4 Device restart ...

Page 474: ...roblems with the time synchronization the clock is displayed in red Messages Opens the device messages Only the admin can delete these messages User Displays the user logged in You can log out and change your password using the menu Passwords can also be changed in the DCA device settings see chapter 7 2 2 4 WebUI Users parameter page Language Selects the language for the web user interface This s...

Page 475: ...olls to this point If you scroll in the dashboard the actual position in the navigation menu is displayed Hide the navigation menu by clicking the button on the left of the screen 9 2 4 ASM detailed view Open the detailed view of the ASM by clicking the ASM s tile The ASM detailed views are explained in chapter 7 in the descriptions of the individual ASMs Several users can be logged in at the same...

Page 476: ......

Page 477: ...ance free In the event of damage e g during transport and or storage repairs are not allowed to be made 10 2 Cleaning Disconnect the device from the supply of electrical power before cleaning If devices become dirty they can be cleaned using a dry cloth or a cloth dampened with a soapy solution Corrosive agents or solutions must never be used ...

Page 478: ...er interface see chapter 7 2 3 2 Firmware update parameter page The device configuration is deleted during the update Only the physical KNX address and the IP configuration are retained All values and states saved are lost The configuration must be programmed again by means of an ETS download You will find the current version of the ETS application program in ETS in the device properties For furth...

Page 479: ...l AC S 1 x 1 2CDC508198D0211 Rev A 479 11 Disassembly and disposal 11 1 Removal Fig 10 Removal 1 Press on the top of the device 2 Release the bottom of the device from the DIN rail 3 Lift the device up and off the DIN rail 2CDC072012F0015 ...

Page 480: ... proper disposal Always dispose of packaging material and electrical devices or their components at collection points or disposal companies authorized for this purpose The products comply with the statutory requirements particularly the law on electrical and electronic equipment and the REACH regulation EU directive 2012 19 EU WEEE and 2011 65 EU RoHS EU REACH regulation and the law implementing t...

Page 481: ...pplication examples You will find application examples in the engineering guides at www abb com knx 12 2 Several devices per system Several devices can be used per system These can exchange data with each other using group addresses You can refer to other devices in the web user interface with the aid of the Link ASM Configurations can be copied between devices See chapter 6 5 8 Copying cutting an...

Page 482: ......

Page 483: ...upplied with the following parts The items delivered should be checked against the list below 1 application controller alternatively o AC S 1 1 1 Application Controller Basic o AC S 1 2 1 Application Controller BACnet 1 x installation and operating instructions 1 x bus connection terminal red black 1x KNX connection cover cap ...

Page 484: ...ABB i bus KNX Appendix 484 2CDC508198D0211 Rev A AC S 1 x 1 13 2 Notes ...

Page 485: ...ABB i bus KNX Appendix AC S 1 x 1 2CDC508198D0211 Rev A 485 Notes ...

Page 486: ...ABB i bus KNX Appendix 486 2CDC508198D0211 Rev A AC S 1 x 1 Notes ...

Page 487: ......

Page 488: ...t of this document at any time without advance notice The agreed properties are definitive for any orders placed ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Reproduction transfer to third parties or processing of the con...

Reviews: