background image

 

 
2TLC172163M0201 Rev.F

 

15

 

 

10

 

Technical data  

Further information about the product and accessories is found at: 

new.abb.com/low-voltage/products/safety-products

 

Stated technical data apply when power supply voltage is +24 VDC and ambient temperature 
is +25 

°

C, unless stated otherwise. 

Manufacturer 

Address 

ABB Electrification Sweden AB 
SE-721 61 Västerås 
Sweden 

Order code/Ordering data

 

2TLA030054R0010: INCA 1 Tina v2 Emergency stop 
button, red button, 5-pin screw terminal block  
2TLA030054R0210: INCA 1S Tina v2 Safety stop 
button, black button, 5-pin screw terminal block 
2TLA030054R1400: INCA 1EC Tina Emergency stop 
button, red button, 5-pin screw terminal block, 
StatusBus 

Power supply  

Required power supply type 

PELV/SELV, not intended to be connected to a DC 
distribution network. 

Note:

 A DC distribution network is defined in 

IEC 61326-3-1:2017 as “Local DC electricity supply 
network in the infrastructure of a certain site or 
building intended for connection of any type of 
equipment”. 

Operating voltage 

+24 VDC +15 %, -25 % 

Total current consumption 

Maximum: 35 mA

RMS

 

Note: 

Total current consumption is the internal supply current when there is no 

information output current. Valid over the operating voltage and ambient temperature 
range.

 

DYNlink signal   

DYNlink Input signal voltage 

Minimum:   8 V

RMS 

Maximum: 15 V

RMS

 

DYNlink Output signal voltage 

Minimum:   8 V

RMS 

Maximum: 15 V

RMS 

Note: 

The purpose of stating the voltage in RMS is to facilitate the measurement of the 

square-wave DYNlink signal with a multimeter.

 

Time delay between DYNlink 
input and output signal (T

DELAY

Maximum: 70 

µ

Information output 

Output voltage high 
                                low 

Nominal: Operating voltage - 2 VDC

 

Maximum: 2 VDC 

Output current 

Maximum: 10 mA 

General  

Protection class 

IP65, connection terminal IP20 

Ambient temperature 

Operation: -10 to +55 °C 
Storage: -30 to +70 °C 

Summary of Contents for INCA 1 Tina v2

Page 1: ...2TLC172163M0201 Rev F ORIGINAL INSTRUCTIONS new abb com low voltage products safety products SAFETY PRODUCTS INCA Tina Emergency stop buttons and INCA Tina Safety stop button Product Manual ...

Page 2: ...use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life ...

Page 3: ... 7 4 1 Installation precautions 7 4 2 Testing safety functions 7 5 Connections 8 5 1 Connection examples 9 6 Functions 10 6 1 LED Indications 10 6 2 LED Indications for StatusBus 10 6 3 Information output signal attributes 10 6 4 Information output signal for StatusBus 11 7 Maintenance 12 7 1 Maintenance precautions 12 8 Troubleshooting 13 8 1 LED indications 13 9 Dimensions 14 10 Technical data 1...

Page 4: ...sumed that the reader of this document has knowledge of the following Basic knowledge of ABB safety products Knowledge of machine safety 1 4 Special notes Pay attention to special notes in the document Warning Risk of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Risk of damage to the equipmen...

Page 5: ...tions standards and the Machinery directive Warning Failure to comply with instructions operation that is not in accordance with the use prescribed in the instructions improper installation or handling of the device can affect the safety of people and the plant Warning For installation and prescribed use of the product the special notes in the instructions must be carefully observed and the techni...

Page 6: ...usBus configured for static information output but it switches to StatusBus configuration when StatusBus communication is detected on the information output A LED in the top of the button indicates the present status of the safety circuit All INCA Tina models are intended for use in safety circuits in accordance with EN 60204 1 Warning The emergency stop safety stop normally needs to be supplement...

Page 7: ...all be tested before starting up the system 4 2 Testing safety functions After each step the status of the input can be read on the monitoring device Steps for testing LED indication DYNlink signal output 1 Interrupt the DYNlink safety circuit before the unit to be tested Green red flashing Shall go low 2 Close the DYNlink safety circuit Green Shall generate a DYNlink signal 3 Interrupt the DYNlin...

Page 8: ...ns 5 pin screw terminal block 1 24 VDC 2 DYNlink signal input 3 0 VDC 4 DYNlink signal output 5 Information output Warning Information output signals shall never be used for safety purpose s For INCA 1EC Tina Information StatusBus output ...

Page 9: ...ontroller or a safety PLC When a safety PLC is used the status of each individual INCA unit can be monitored on separate PLC ports INCA 1EC Tina Three INCA 1EC Tina with StatusBus connected to the DYNlink safety circuit monitored by a safety PLC The status of each individual INCA 1EC Tina unit can be monitored with a single PLC port in a controller having a StatusBus master ...

Page 10: ...us mode on Address 0 Device not addressed Off for 5 sec then flickering flash 0 07 1 9 s on off The flashing usually lasts for 1 4 seconds during the addressing process If the condition lasts for more than 4 seconds Device failure when addressing change address Scours with stress flash Scouring cycle 0 8 0 4 s on off Flash frequency 0 02 0 03 s on off At the command from StatusBus Master Device id...

Page 11: ...formation output signal attributes StatusBus The information output from several devices with StatusBus functionality can be connected to one and the same port on a StatusBus master Then the StatusBus master can configure the devices to report their status one at a time For more information about the StatusBus see the user manual for the StatusBus master used e g Pluto Programming Manual found at ...

Page 12: ... tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 A1 2013 A2 2015 EN ISO 13849 1 2015 Warning In case of breakdown or damage to the product contact ABB Do not try to repair the product yourself since it may accidentally cause permanent damage to the product impairing the safety of the device which in turn could lead to serious in...

Page 13: ...24 VDC connected to DYNlink signal input Check if there is 24 VDC on DYNlink signal input If yes check cable connections or the unit before No LED light Loss of power supply Check 24 VDC 0 VDC power supply Green but no DYNlink output detected Defective DYNlink signal input to unit Check the DYNlink input or the unit before Weak lights Unit is defective Replace the unit ...

Page 14: ...2TLC172163M0201 Rev F 14 9 Dimensions All dimensions are in mm Mounting cut out ...

Page 15: ...etwork is defined in IEC 61326 3 1 2017 as Local DC electricity supply network in the infrastructure of a certain site or building intended for connection of any type of equipment Operating voltage 24 VDC 15 25 Total current consumption Maximum 35 mARMS Note Total current consumption is the internal supply current when there is no information output current Valid over the operating voltage and amb...

Page 16: ...force Emergency stop button 17 4 N Actuating travel 5 mm Mechanical lifetime 250 000 cycles Note The maximum number of operations cycles for INCA Tina emergency stop is 6050 to reach PL e and the given PFHD value Directives Harmonized standards Conformity European Machinery Directive 2006 42 EC EN ISO 12100 2010 EN 62061 2005 Cor 2010 A1 2013 A2 2015 EN ISO 13849 1 2015 EN 60204 1 2018 IEC EN 6150...

Page 17: ...2TLC172163M0201 Rev F 17 11 Declaration of conformity EC Declaration of conformity Pending ...

Page 18: ...2TLC172163M0201 Rev F 18 UK Declaration of conformity ...