32
—
Technical data
AC input
Charging type
Mode 3 charging, level 2
Input/output power rating and current
9.6 kW / 40 A, 19.2 kW / 80 A
Input/ouput voltage, frequency
208 / 240 Vac, 50 / 60 Hz
Network type
TT, TN
Cable type / Cable storage
SAE J1772, type 1 cable, 25 ft (7.6 m). Cable is wrapped around charger and front holster inlet
Protections
Overcurrent, overvoltage, undervoltage, integrated surge protection
Ground fault circuit interrupter
Integrated 20 mA AC CCID, no addiontal required
Overvoltage category
III
Energy metering
Revenue grade energy meter Class B (±2%)
Rotary switch set current limit options 80 A model
10 A / 16 A / 24 A / 32 A / 40 A / 48 A / 56 A / 64 A / 80 A
Rotary switch set current limit options 40 A model
10 A / 16 A / 24 A / 32 A / 40 A
Stand-by mode power consumption
3 W / 5.6 W with display
Power-down backup capacitor
Able to store charge transaction during power down
Noise level
Less than 40 dB (A)