IP54 sealing gasket for RVT 

Technical specification

The IP54 sealing for RVT gives a protection from the front panel 
side.

 

− IP5X :

•  Dust-protected. Ingress of dust is not totally prevented,  

 

but dust shall not penetrate in a quantity to interfere  

 

with satisfactory operation of the apparatus or to impair  

 safety.

•  Wire protected. Protected against access to hazardous  

 

parts with a wire of diameter 1 mm.

 

− IPX4 : 

•  Protected against splashing water. Water splashed    

 

against the enclosure from any direction shall have no  

 

harmful effects.

IP54 sealing installation

Step 1: Slide the RVT (a) perpendicularly to the capacitor bank 
cubicle. 

Step 2: Rotate the RVT (b) to insert it into the capacitor bank 
cubicle. 

Installation guide

Step 2
(b)

Step 1
(a)

 

Note: cut out dimensions are 138x138 mm.