Reconnecting the axis-3 motor connectors
Note
Action
xx2200000055
Reconnect the connectors.
•
FB3
•
MP3
Tip
See the number markings on the connectors for
help to find the corresponding connector.
1
xx2200000054
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Grease: 3HAC029132-001
Apply grease to the cable package, cover all
moving area of the package.
3
Securing the cable package in axis 4
Note
Action
Cable bracket, axis 4:
3HAC076867-001
Refit the axis-4 cable bracket to the cable.
1
Screw: M2.5x4 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 0.6 Nm
xx2200000558
Continues on next page
Product manual - IRB 1010
147
3HAC081964-001 Revision: B
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued