Note
Action
xx2200000036
Remove the axis-5 cable protector.
Note
The screws to be removed are a little protruding
than others. Do not mix the screws.
3
xx2200000037
Pull out the cable package in the direction as
shown in the figure.
4
Slip out the cable protector.
5
Separating the cable package from axis 5
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2200000038
Remove the axis-5 cable bracket.
CAUTION
Be aware of the cablings that are attached to the
cable bracket! The bracket cannot be removed
completely until the cablings are removed from
the plate.
2
xx2200000039
Cut the cable strap.
3
Continues on next page