Note
Action
xx1900000009
Remove the adjustment screw from the motor.
12
Reconnecting the axis-3 motor connectors
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx1800003005
Slide the connectors into the connector plate and
reconnect the connectors.
•
FB3
•
MP3
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
Product manual - IRB 1100
161
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the upper cable package
Continued