Note
Action
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx1800002499
Remove the cable bracket.
3
Disconnecting the air hoses, CP/CS cabling and Ethernet cabling (if equipped)
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx1800002500
Disconnect the air hoses from the Y-shaped con-
nectors.
3
Continues on next page
Product manual - IRB 1100
187
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the lower cable package
Continued