Reconnecting the brake release cabling and axis-1 motor connectors
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx1800003054
Reconnect the connectors.
•
J1M.BR
•
MP1
•
FB1
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Reconnect the floor cable together with the con-
nector plate.
3
Tightening torque: 0.8 Nm
xx1800003037
xx1800003036
Continues on next page
Product manual - IRB 1100
209
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the lower cable package
Continued