Note
Article number
Spare part
Battery includes protection cir-
cuits. Only replace with the spe-
cified spare part or an ABB-ap-
proved equivalent.
3HAC044075-001
Battery pack
Required tools and equipment
Note
Article number
Equipment
Content is defined in section
.
-
Standard toolkit
Delivered as a set of calibration
tools.
Required if Axis Calibration is the
valid calibration method for the
robot.
The tool box also includes a
unique calibration pin for IRB
1100 to be fitted to the tool flange
during calibration of axis 6.
3HAC074119-001
Calibration tool box, Axis Calibra-
tion
Used to release the motor brakes.
-
24 VDC power supply
Required consumables and wear parts
Note
Article number
Consumable
-
Cable straps
FM 222
3HAC029132-001
Grease
Loctite 243
3HAB7116-1
Locking liquid
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
Note
Action
Note
Calibrating axis 6 always requires tools to
be removed from the mounting flange (also
for reference calibration) since the mount-
ing flange is used for installation of the
calibration tool.
Decide which calibration routine to use for
calibrating the robot.
•
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
•
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
1
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
Product manual - IRB
4600
.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
Continues on next page
Product manual - IRB 1100
221
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the SMB unit
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...