Note
Action
xx1800003054
Reconnect the connectors.
•
J1M.BR
•
MP1
•
FB1
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Reconnect the floor cable together with the con-
nector plate.
3
Tightening torque: 0.8 Nm
xx1800003037
xx1800003036
Continues on next page
Product manual - IRB 1100
269
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 738: ...This page is intentionally left blank ...
Page 760: ...This page is intentionally left blank ...
Page 764: ......
Page 765: ......