Note
Action
xx1800002496
Remove the timing belt from its groove on the
motor.
13
Loosening the cable package from axis-1 gearbox
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx1800003032
Access the cable package locking screw on the
axis-1 gearbox from the swing and then loosen
the locking screw.
3
Remove the locking screw.
4
Continues on next page
290
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued