Checking the radial sealing on the swing support (IP67 or Clean Room)
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx1900002201
Check the radial sealing on the swing support.
Replace if damaged, as described below.
2
Grease: 3HAC029132-001
Apply a little grease to the new sealing when re-
placing the radial sealing and wipe clean after the
replacement.
3
xx1900002157
Place the new sealing in its groove in the swing
support.
4
Axis-2 radial sealing assembly tool,
included in the radial sealing as-
sembly tool set 3HAC074609-001.
xx1900002158
Place the dish-shaped plate of the radial sealing
fitting tool against the radial sealing.
5
Fit the circular plate to the other side of the swing
support with six M6x50 screws.
6
Continues on next page