Note
Action
xx1800003031
Valid for IRB 1100-4/0.475
Access the cable package locking screw on the
axis-4 gearbox from the wrist and then loosen the
locking screw.
3
xx1800003000
Valid for IRB 1100-4/0.58
Remove the plug screw and washer on the ex-
tender unit to access the cable package locking
screw on the axis-4 gearbox and then loosen the
locking screw.
4
xx1800003001
Disconnecting the axis-4 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
396
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 738: ...This page is intentionally left blank ...
Page 760: ...This page is intentionally left blank ...
Page 764: ......
Page 765: ......