Note
Action
xx1900002160
Place the new sealing in its groove in the lower
arm support.
4
Axis-3 radial sealing assembly tool,
included in the radial sealing as-
sembly tool set 3HAC074609-001.
xx1900002161
Place the dish-shaped plate of the radial sealing
fitting tool against the radial sealing.
5
Fit the circular plate to the other side of the lower
arm support with six M6x50 screws.
6
xx1900002162
Screw the screws, little by little, to press the
sealing into place.
7
Remove the assembly tool.
8
Check that the sealing is undamaged and properly
fitted.
9
Securing the lower arm support
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Continues on next page
Product manual - IRB 1100
415
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 738: ...This page is intentionally left blank ...
Page 760: ...This page is intentionally left blank ...
Page 764: ......
Page 765: ......