Note
Action
xx1800003025
Reconnect the connectors.
•
FB5
•
MP5
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Insert the cabling and connectors into the wrist.
4
Refitting the process hub
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Gasket for process hub:
3HAC065352-001
xx1900002187
For robots with protection class IP67 (option
3350-670)
For robots with protection type Clean Room
(option 3351-4)
Check the gasket.
Replace if damaged.
2
Continues on next page
436
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued