Note
Action
xx1800002945
Reconnect the air hoses in a cross pattern.
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same Y-shaped connector.
3
xx1800002947
For robots with CP/CS cabling
Reconnect the connector.
•
J5.C1
4
J5.C2 connector assembly tool, in-
cluded in the special toolkit
3HAC071022-001
xx1800002948
For robots with Ethernet cabling
Reconnect the connector J5.C2 using the tool.
5
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
6
Continues on next page
Product manual - IRB 1100
437
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued