Note
Action
xx1800003092
Remove the lower arm support cover.
3
xx1800003093
Pull out the upper cable harness from the housing,
out from the lower arm support.
4
Removing the axis-4 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
3
Continues on next page
456
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the extender unit and wrist
Continued