Note
Action
Apply grease to the covers that have contacting
area with the cable package.
4
Screw: M3x8 12.9 Lafre
2C2B/FC6.9
Refit the covers.
•
Lower arm cover
•
Lower arm support cover
5
Tightening torque: 1.2 Nm
xx1800003608
Concluding procedure
Note
Action
For robots with protection type Clean Room:
1
Clean and paint the joints that have been opened.
See
Cut the paint or surface on the robot before
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
Calibration is detailed in section
Recalibrate the robot.
2
DANGER
Make sure all safety requirements are met when
performing the first test run.
3
Product manual - IRB 1100
535
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.7.3 Replacing the axis-3 motor
Continued