Note
Action
Cable protection tube orientation:
use the notch (A) on the cable pro-
tection tube as a reference when
inserting the cable package, which
should be at the opposite direction
to the locking screw hole (B) on the
gearbox.
xx1800003017
Insert the cable package in the housing and
through the axis-4 gearbox.
Tip
Wrap the connectors with the masking tape.
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
2
xx1800003601
Securing the upper cable package to the axis-4 gearbox
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Continues on next page
Product manual - IRB 1100
699
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.8.4 Replacing the axis-4 gearbox
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 738: ...This page is intentionally left blank ...
Page 760: ...This page is intentionally left blank ...
Page 764: ......
Page 765: ......