Note
Action
Plug screw: 3HAC064146-001
Valid for IRB 1100-4/0.58
4
For robots with protection type
Clean Room (option 3351-4)
Refit the plug screw and washer on the extender
unit.
Plug screw, Clean Room:
3HAC070309-001
For robots with protection class
IP67 (option 3350-670)
For robots with protection type
Clean Room (option 3351-4)
Rubber sealing washer on extender
unit: 3HAC067995-001
Tightening torque: 2 Nm
xx1800003000
Reconnecting the axis-4 motor connectors
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx1800003618
Check the cabling status.
Make sure the cabling is in vertical state and is
not twisted.
2
Continues on next page
702
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.8.4 Replacing the axis-4 gearbox
Continued