Note
Action
xx1800002994
Reconnect the connectors.
•
FB6
•
MP6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Insert the cabling and connectors into the wrist.
4
Reconnecting the axis-5 motor connectors
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx1800003025
Reconnect the connectors.
•
FB5
•
MP5
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Insert the cabling and connectors into the wrist.
4
Continues on next page
706
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.8.4 Replacing the axis-4 gearbox
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 738: ...This page is intentionally left blank ...
Page 760: ...This page is intentionally left blank ...
Page 764: ......
Page 765: ......