Information
Action
xx1400002906
Carefully remove
motor axis 5
.
18
Disconnect air hoses.
19
Removing the cable harness in the
upper arm housing
Information
Action
CAUTION
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of a Clean Room robot! See
1
xx0900001018
Unscrew the
two attachment screws
secur-
ing the
cable harness
in the bracket. Leave
the bracket fastened in the housing.
2
Parts:
•
A: Attachment screws (4 pcs)
•
B: Cable bracket
•
(C: Axis 5 shall be in 90° position)
Continues on next page
126
Product manual - IRB 120
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.3.1 Removing the cable harness
Continued