Information
Action
Carefully pull the cable harness through the
swing plate.
CAUTION
Cable harness and hoses are sensitive
equipment. Use caution when handling
cable harness.
5
xx0900000836
Place the
cables
from cable harness on the
right side in frame, and the
air hoses
on the
left side in the frame.
6
Tightening torque: 1 Nm.
xx0900000884
Secure the cable harness to the
cable holder
with the
attachment screws
.
7
Parts:
•
A: Swing plate
•
B: Cable holder
•
C: Attachment screws (2 pcs)
•
D: Cable ties (4 pcs)
Carefully push and pull the cable harness
out from the frame.
CAUTION
Cable harness and hoses are sensitive
equipment. Use caution when handling
cable harness.
8
Put some cable grease on the cable harness
(including air hoses).
9
Continues on next page
136
Product manual - IRB 120
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.3.2 Refitting the cable harness
Continued