Removing motor axis 5 with pulley
Use this procedure to remove motor axis 5 with pulley.
Information
Action
DANGER
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
1
CAUTION
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of a Clean Room robot! See
2
xx0900000886
Remove the
wrist side covers
on both sides
of the wrist.
3
Parts:
•
A: Wrist side covers (2 pcs)
xx0900000887
Loosen the
attachment screw
securing the
clamp
.
4
Parts:
•
A: Attachment screw
•
B: Clamp
Continues on next page