Information
Action
xx0900000857
Remove
cable guide
.
11
Parts:
•
A: Attachment screws (2 pcs)
•
B: Cable guide
Removing the cable harness in the
base
Information
Action
CAUTION
Always cut the paint with a knife and grind
the paint edge when disassembling parts
of a Clean Room robot! See
1
The picture will be good help when assem-
bling the bracket again.
xx1500000001
If the cable harness is being reused:
•
Take a picture of the bracket (from
the wrist) mounted on the harness
•
Place a cable tie close to the bracket
•
Cut old cable ties
2
Remove the bracket (from the wrist) on the
cable harness.
3
Tighten the screw after removal of bracket.
4
Guide the cable harness and pull it carefully
in below motor in axis 2.
5
Tip
Take a picture of cable harness placement
in the swing housing before removal.
6
Continues on next page
130
Product manual - IRB 120
3HAC035728-001 Revision: N
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.3.1 Removing the cable harness
Continued