Note
Action
Article number is specified in
A
B
C
xx2000000071
A Main lip
B Grease
C Dust lip
Lubricate the sealing with grease just before fitting.
(Not too early - there is a risk of dirt and foreign
particles adhering to the sealing.)
Fill 2/3 of the space between the dust lip and the main
lip with grease. If the sealing is without dust lip, just
lubricate the main lip with a thin layer of grease.
3
A
xx2000000072
A Gap
Mount the sealing correctly with a mounting tool.
Never hammer directly on the sealing as this may
result in leakage.
4
Make sure that no grease is left on the robot surface.
5
Continues on next page
Product manual - IRB 1300
143
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.1 Mounting instructions for sealings
Continued