Note
Action
xx2000001531
Remove the connector plates.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
4
Disconnecting the axis-6 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx2000001532
Disconnect the connectors.
•
MP6
•
FB6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
3
xx2000001533
Snap loose and remove the male head of the
connectors from the connector plate.
4
Continues on next page
Product manual - IRB 1300
157
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued