Note
Action
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx2000001564
Remove the axis-1 connector plate.
3
Wrap the connectors with the masking tape.
4
xx2000001563
Pull out the cable package in the direction as
shown in the figure.
Note
Slip out the cable protectors while pulling out the
cable package.
5
Slip out the cable protectors.
6
Refitting the cable package
Use these procedures to refit the cable package.
Securing the cable package in the base
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Wrap the connectors with the masking tape.
2
Continues on next page
Product manual - IRB 1300
171
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued