Note
Action
xx2000001549
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
xx2000001550
Reconnect the connectors.
•
FB2
•
MP2
•
FB3
•
MP3
Tip
See the number markings on the connectors for
help to find the corresponding connector.
4
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate to the lower arm.
5
Tightening torque: 2.6 Nm
xx2000001548
Securing the cable package in the lower arm
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Continues on next page
178
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package