Note
Action
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx2000001542
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
3
xx2000001543
Cut the cable strap.
Note
The motor cablings have another strap fixed. Al-
ways cut the strap that fixes the cable package
to the plate.
4
xx2000001544
Disconnect the connectors.
•
MP4
•
FB4
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
5
xx2000001545
Snap loose and remove the male head of the
connectors from the connector plate.
6
Continues on next page
Product manual - IRB 1300
251
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued
Summary of Contents for IRB 1300
Page 1: ...ROBOTICS Product manual IRB 1300 ...
Page 8: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 746: ...This page is intentionally left blank ...
Page 762: ...This page is intentionally left blank ...
Page 764: ...This page is intentionally left blank ...
Page 768: ......
Page 769: ......