Note
Action
xx2000001544
Reconnect the connectors.
•
FB4
•
MP4
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
xx2000001543
Route and secure the cabling with a cable strap.
Note
The motor cablings have another strap fixed. Pay
attention to the location where the new strap to
be fixed, see the figure as a guidance.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
4
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate.
5
Tightening torque: 2.6 Nm
xx2000001542
Routing the cable package in the tubular
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Continues on next page
Product manual - IRB 1300
279
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued
Summary of Contents for IRB 1300
Page 1: ...ROBOTICS Product manual IRB 1300 ...
Page 8: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 746: ...This page is intentionally left blank ...
Page 762: ...This page is intentionally left blank ...
Page 764: ...This page is intentionally left blank ...
Page 768: ......
Page 769: ......