Replacing the axis-2 mechanical stops
Note
Action
Jog the robot to a position where the mechanical
stops are most easily accessed.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
2
xx2000000506
Remove the mechanical stops.
3
Mechanical stop, block A:
3HAC065651-001 (2 pcs)
Discard the old stops and refit with new ones.
4
Apply a little Loctite 243 to the screws.
Note
If there is locking liquid residues on the screw,
please clean it before refitting. Remove residual
locking liquid after refitting.
5
Screw: M4x16 stainless steel (1
pcs per stop)
Secure the mechanical stops.
6
Tightening torque: 1 Nm
Product manual - IRB 1300
293
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.4.4 Replacing the axis-2 mechanical stops
Continued
Summary of Contents for IRB 1300
Page 1: ...ROBOTICS Product manual IRB 1300 ...
Page 8: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 746: ...This page is intentionally left blank ...
Page 762: ...This page is intentionally left blank ...
Page 764: ...This page is intentionally left blank ...
Page 768: ......
Page 769: ......