Removing the lower arm
Use these procedures to remove the lower arm.
Preparations before removing the lower arm
Note
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
Jogging the robot to oil draining position
Note
Action
xx2000001519
Jog the robot to the specified position:
•
Axis 1: 0°
•
Axis 2: -67.5
•
Axis 3: 0°
•
Axis 4: 0°
•
Axis 5: 0°
•
Axis 6: No significance.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
2
Draining oil of axis-2 gearbox
Note
Action
WARNING
Handling gearbox oil involves several
safety risks, see
1
Continues on next page