Required tools and equipment
Note
Article number
Equipment
Content is defined in section
.
-
Standard toolkit
Delivered as a set of calibration
tools.
Required if Axis Calibration is the
valid calibration method for the
robot.
3HAC074119-001
Calibration toolbox, Axis Calibra-
tion
Used to release the motor brakes.
-
24 VDC power supply
Used for measuring the timing
belt tension.
-
Sonic tension meter
Included in special toolkit
3HAC076396-001.
-
Tension adjustment tool for axis-4
timing belt
Used for measuring the timing
belt tension.
-
Dynamometer
Used with protection class IP67,
and protection types Clean Room
and Foundry Plus.
Used for the press-fitting of radial
sealings. Includes five sets of ra-
dial sealing assembly tool for
axes 1 to 4 and axis 6.
3HAC078203-001
Special toolkit for IP67/Clean
Room/Foundry Plus robots
Required consumables
Note
Article number
Consumable
-
Cable straps
FM 222
3HAC029132-001
Grease
Loctite 574
-
Flange sealant
Isopropanol
-
Cleaning agent
Removing the tubular and tilt unit (IRB 1300-11/0.9 and IRB 1300-10/1.15)
Use these procedures to remove the tubular and tilt unit for IRB 1300-11/0.9 and
IRB 1300-10/1.15.
Preparations before removing the tubular and tilt unit
Note
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
1
Continues on next page
416
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued
Summary of Contents for IRB 1300
Page 1: ...ROBOTICS Product manual IRB 1300 ...
Page 8: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 746: ...This page is intentionally left blank ...
Page 762: ...This page is intentionally left blank ...
Page 764: ...This page is intentionally left blank ...
Page 768: ......
Page 769: ......