Note
Action
Tightening torque: 6 Nm
xx2000001599
Secure the motor with the screws.
5
Refitting the axis-5 motor
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
•
all assembly surfaces are clean and without
damages
•
the motor is clean and undamaged.
2
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx2000001598
Orient the motor correctly and fit it into the tubular.
3
Screw: M5x16 12.9 Lafre
2C2B/FC6.9 (4 pcs)
xx2000001596
Refit the screws and washers.
Note
Do not tighten the screws yet.
4
Continues on next page
478
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued