Note
Article number
Spare part
Used with protection type Clean
Room.
3HAC077837-001
Process hub, Clean Room (CP/CS
and air hose, without Ethernet)
Used with protection type Clean
Room.
3HAC077838-001
Process hub, Clean Room (CP/CS
and air hose, with Ethernet)
Used with protection classes IP40
and IP67.
Used with protection type
Foundry Plus.
3HAC073094-001
Tubular cover
Used with protection type Clean
Room.
3HAC077823-001
Tubular cover, Clean Room
Not used with protection class
IP40.
Replace if damaged.
3HAC070887-001
Gasket for process hub
Not used with protection class
IP40.
Replace if damaged.
3HAC067834-001
Gasket for tubular cover
Not used with protection class
IP40.
Replace if damaged.
3HAC032050-001
Seal bolt
Required tools and equipment
Note
Article number
Equipment
Content is defined in section
.
-
Standard toolkit
Delivered as a set of calibration
tools.
Required if Axis Calibration is the
valid calibration method for the
robot.
3HAC074119-001
Calibration toolbox, Axis Calibra-
tion
Used to release the motor brakes.
-
24 VDC power supply
Used for measuring the timing
belt tension.
-
Sonic tension meter
Required consumables
Note
Article number
Consumable
-
Cable straps
FM 222
3HAC029132-001
Grease
Continues on next page
546
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the axis-5 motor
Continued
Summary of Contents for IRB 1300
Page 1: ...ROBOTICS Product manual IRB 1300 ...
Page 8: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 746: ...This page is intentionally left blank ...
Page 762: ...This page is intentionally left blank ...
Page 764: ...This page is intentionally left blank ...
Page 768: ......
Page 769: ......