Note
Action
xx2000001537
Snap loose and remove the male head of the
connectors from the connector plate.
4
Removing the axis-5 timing belt
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
CAUTION
Loosening timing belts will release axes. This
means the axes can fall down.
Make sure axes are well supported before
loosening timing belts.
3
xx2000001594
Loosen the screws and move the motor slightly
to slacken the timing belt.
4
Continues on next page
Product manual - IRB 1300
553
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the axis-5 motor
Continued